CM-200GE/CM-200GE-RA/CB-200GE/CB-200GE-RA- 45 -10.2.4 Reset Continuous (RCT) trigger modeThe RCT mode operates like EPS (edge preselect) mode with smearless function. Anexternal trigger pulse will immediately stop the video read out, reset and restart theexposure, then operate as normal mode until the next trigger. After the trigger pulse isinput, a fast dump readout is performed. In the CM-200GE/ CB-200GE, this period is8.3307ms which is 179L. The exposure time is determined by the pre-set shutter speed. Ifno further trigger pulses are applied, the camera will continue in normal mode and thevideo signal is not output. The fast dump read out has the same effect as “smearless readout”. Smear over highlight areas is reduced for the trigger frame. The reset continuoustrigger mode makes it possible to use triggering in conjunction with a lens with videocontrolled iris.To use this mode:Important notes on using this mode Trigger pulse >2 LVAL to <1 FVAL) The following table shows minimum trigger interval in asynchronous accumulation modeFull scan 1439 L2/3 Partial 1076 L1/2 Partial 898 L1/4 Partial 634 L1/8 Partial 504 L1/2 V Binning 815 L