- 3 -TO LOAD A DEFAULT SET:While in Program mode, press ✻97, then enter a number 1-4 corresponding to the default table desired. Seethe Installation Instructions for the default tables. Enter 0 if you are not selecting a default table.TO EXIT PROGRAMMING MODE:✻98 Exits programming mode and prevents re-entry by: Installer Code + 8+ 0 + 0. If ✻98 is used to exit programmingmode, system must be powered down, then press [✻] and [#] within 50 seconds of power up to re-enterprogramming mode.✻99 Exits programming mode and allows re-entry by: Installer Code + 8 + 0 + 0 or: Power-up, then press [✻] and [#]within 50 seconds of power up.DATA FIELDSField Function Programmed Values [ ] = Table 1 Default ValuesSYSTEM SETUP (✱ 20– ✱ 30)✱20 INSTALLER CODE [4112]Enter 4 digits, 0–9✱21 QUICK ARM ENABLE † [1]0 = no; 1 = yes✱22 KEYPAD BACKLIGHT TIMEOUT [0]0 = none (backlighting always on); 1 = backlight off after 10secs✱23 FORCED BYPASS † [0]0 = none; 1 = bypass open zonesUL installations = 0✱24 RF HOUSE ID CODE | [00]00 = disable all wireless keypad usage;01–31 = 5804BD/5804BDV house ID✱25 POWERLINE CARRIER DEVICEHOUSE CODE [0]0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G, 7 = H, 8 = I,9 = J, #10 = K, #11 = L, #12 = M, #13 = N, #14 = O, #15 = P✱26 CHIME BY ZONE † [0]0 = no; 1 = yes (program zones to chime on zone list 3)✱27 REAL TIME CLOCK DISPLAY † [1]0 = no; 1 = yes, display time on keypad✱29 DAYLIGHT SAVING TIMESTART/END MONTH [3, 11]Start End1-9, #+10,#+11,#+12. Enter 0,0 if no daylight savings time used.✱30 DAYLIGHT SAVING TIMESTART/END WEEKEND [2,1]Start End0=disable; 1=first; 2=second; 3=third; 4=fourth;5=last; 6=next to last; 7=third from lastZONE SOUNDS AND TIMING (✱✱✱✱ 31– ✱✱✱✱ 39)✱31 SINGLE ALARM SOUNDING/ZONE † [0]0 = Alarm Sounding Per Zone will be the same as the SwingerShutdown” set in field *92;1 = yes, limit once per arming period (also applies to long rangeradio output if “0” is selected in ✻91 field)UL installations = 0† Entering a number other than the one specified may give unpredictable results.