PROGRAMMING MODE COMMANDSCompatibility: This document applies to systems with microprocessor version 9.1 or higher.TO ENTER PROGRAMMING MODE (using an alpha keypad connected to the control):A. POWER UP, then press [!] and [#] at the same time, within 50 seconds of powering up (this method must be used if !98was used to exit program mode). ORB. Enter Installer Code (4112) then 8 0 0.PROGRAMMING COMMANDSTask Command/ExplanationGo to a Data Field Press [∗∗∗∗] + [Field Number], followed by the required entry.Entering Data When the desired field number appears, simply make the required entry. When the last entryfor a field is entered, the keypad beeps three times and automatically displays the next datafield in sequence. If the number of digits that you need to enter in a data field is less than themaximum digits available (for example, the phone number fields *41, *42), enter the desireddata, then press [∗ ] to end the entry. The next data field number is displayed.Review a Data Field Press [#] + [Field Number].Data will be displayed for that field number. No changes will be accepted in this mode.Deleting an Entry Press [∗∗∗∗] + [Field Number] + [∗∗∗∗]. (Applies only to fields ∗40 thru *46, *94, and pager fields)Initialize Download ID Press ∗∗∗∗96. Initializes download ID and subscriber account number.Reset Factory Defaults Press ∗∗∗∗97. Sets all data fields to original factory default values.Zone Programming Press ∗∗∗∗56. Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800RF transmitters.Function Key Programming Press ∗∗∗∗57. Unlabeled keypad keys (known as ABCD keys) for special functionsZone Programming(Expert Mode)Press ∗∗∗∗58. Same options as *56 mode, but with fewer prompts. Intended for those familiarwith this type of programming, otherwise *56 mode is recommended.Output Device Mapping Press ∗∗∗∗79. Assign module addresses and map individual relays/powerline carrier devicesOutput Programming Press ∗∗∗∗80. 4229 or 4204 Relay modules, Powerline Carrier devices, or on-board triggersZone List Programming Press ∗∗∗∗81. Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc.Alpha Programming Press ∗∗∗∗82. Zone alpha descriptorsIP/GSM Programming Press ∗∗∗∗29. For programming the IP/GSM options.Exit Program Mode withinstaller code lockoutPress ∗∗∗∗98. Exits programming mode andprevents re-entry by: Installer Code + 8 0 0.To reenter programming mode, the system must be powered down, then powered up. Thenuse method A above. See field *88 for other *98 Program mode lockout options.Exit Program Mode Press ∗∗∗∗99. Exits program mode andallows re-entry by: Installer Code + 8 0 0 or method Aabove.Scheduling Mode Enter code + [#] + 64. Create schedules to automate various system functions.Site-Initiated Download Installer code + [#] + 1 (perform while system is disarmed and in normal mode)AVS QUICK PROGRAMMING COMMANDS (for AAV sessions using the AVS system)For controls with the following firmware revision levels, these commands automatically configure the control for AVSoperation. VISTA-15P = version 6.0 or higher; VISTA-20P = version 7.0 or higher• installer code + [#] + [0] + 3: enable AVS operation• installer code + [#] + [0] + 4: enable AVS operation and enable panels sounds on the AVST speaker• installer code + [#] + [0] + 5: remove all programming options set by [#] + [0] + 3 quick command• installer code + [#] + [0] + 6: remove all programming options set by [#] + [0] + 4 quick commandRefer to the AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS section for details on the specific optionsthat are set with each command, depending on the control used.To select the AAV session communication path (phone line/communication device), see field ∗55 Dynamic Signaling Priority.To enable AAV operation, use ∗91 Options field (option 4).SPECIAL PROGRAMMING MESSAGES•••• OC = OPEN CIRCUIT (no communication between Keypad and Control).•••• EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).•••• After powering up, AC, dI (disabled) or “Busy Standby vx.x (firmware revision) Dl will be displayed after approximately 4seconds. This will revert to a “Ready” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You canbypass this delay by pressing [#] + [0].NOTE for CANADIAN PANELS: Power up time is 2 minutes, and Contact ID report code 305 System Reset is sent if the[#] + [0] command is not performed before the 2 minutes expires.•••• If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear afteryou correct the programming.IMPORTANT: The Real-Time Clock must be set before the end of the installation. See procedure in the Setting the Real-TimeClock section of this manual.– 4 –