Operating Manual HARTRIDGE LIMITED24 HL030(EN), Issue 1, June 2005To edit a testplan, load it into the main screen then simply change the required demand values orlimits (by clicking in the appropriate box). Step names can also be changed using the [Edit Name]button.NOTE: We advise you NOT to change the example testplans supplied as this will maintain aconsistent base to refer back to if needed. Rather, create a copy of the example plan usingthe [New] button as described above, and then make the required changes to this newtestplan.To save the changes, open the Testplan Menu then click [Save Testplan].NOTE: You are not able to create, edit, or delete Manufacturer information as this is restrictedaccess.4.6 Viewing and Printing Saved ResultsTo view or print previously saved results press F5 [View Results]. This opens a dialog with a drop-down list of previously saved results files. Select the required results file and press [OK]; the softwarewill load it into the main screen.The appearance of the results viewing screen is slightly different from the live data screen; most ofthe functions/areas are disabled (greyed out) as shown below. The results file information in the topleft of the screen shows the date and time saved, the results filename and any comments saved withthe results.You can use the drop-down test step list to view the results from each test step (it also shows thedemands and limits for that test step). You can print the results using F7, or return to the live datascreen by pressing F5 [View Live].Figure 4.8: Injector Screen in Results ViewTHIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.