Code RequirementsYour lift and enclosure have been designed to meet ASME A18.1 section 2 and 5 and CSAB44/ASME A17.5, with the addition of certain options. Code requirements for Vertical Platform lifts varydepending on location.It is the installers’ responsibility to contact their local code enforcement office and determine all of theregulations they are subject to. You must do this before installing the Vertical Platform Lift. If you havequestions about this, feel free to call Harmar to be directed to the right officials.Site Requirements 115vac 20amp grounded circuit, if outdoor, GFI protected.. Minimum 5” thick , level, 3,500 psi reinforced concrete slab sized to your specific install drawing. If you choose to install the lift in a pit so the platform is at floor-level, Harmar recommends that the pitbe sized to install the enclosure in it also.Required tools Step ladder Extension ladder or scaffold (helpful fortall units) Hammer Drill 3/8" Masonry Drill Bit, min 8” long Appliance Dolly Hammer Level Measuring Tape Socket Wrench Set Socket wrench or drill extensions up totwo-feet long (if installing walls fromplatform) Phillips screwdriver or bits, size #2 & #3 Wire stripper and cutter Conduit cutters, punches and toolsneeded with electrical conduitRequired materials Up to 14 concrete anchors, wedge-type. Harmar recommends securing the lift with our Anchor Kit p/nIf you use your own, we recommend 3/8-16 anchor bolts with embedment of 4 inches. These shallhave a min pull out strength of 3000 lbs-force. If used in an extreme environment (wet, salty), usegalvanized or stainless steel Various shims, slotted preferred, but washers can work. Min reqd. about 1/16 th thick, Qty, up to about25 max. These are to align enclosure and lift with the building. Often these aren’t needed. Lag screws or similar and washers to attach upper portion of the enclosure to the building. You mayneed lumber for this step too. Up to ten wire nuts, med size. Caulking, outdoor 25 year-silicone preferred Electrical conduit and fittings. For outdoor installation, use liquid-tite and appropriate fittings4