12GB Fault Possible cause RemedyWatering is not switched on Valve has been closed manually. v Turn Run Time button to aalthough soil is dry watering duration.The control panel has not been v Insert control panelinserted correctly. correctly.Watering is switched on Soil Moisture Sensor not v Position Soil Moisturealthough soil is damp positioned in watering area. Sensor in watering area.Switching controller too far v Turn switching controller toto the right on “Damp”. the left accordingly.Defective or loose sensor cable. v Check sensor cable andconnections.Air trapped at sensor tip. v Remove trapped air (see4. Initial Operation“ “Plant”Soil Moisture Sensor ” ).Automatic Irrigation Set Minimum flow rate below v Connect more drip heads.does not close below 20 l / h.Battery display of Soil Batteries of Soil Moisture v Replace batteries ofSoilMoisture Sensor flashing Sensor spent / inserted Moisture Sensor / insertincorrectly / wrong batteries correctly / use alkalineused. batteries.Soil Moisture Sensor defective. v Contact GARDENA Service.Error indicator of Batteries of Soil Moisture v Replace batteries ofSoil -Water Timer flashing Sensor spent / inserted Moisture Sensor / insertincorrectly / wrong battery correctly / use alkalineused. battery.Batteries of Soil Moisture Sensor v Replace batteries of Soilare flat. Moisture Sensor.Cable of Soil Moisture Sensor v Replace cable of Soildefective. Moisture Sensor.Defective or loose sensor cable. v Check sensor cable andconnections.A In the event of other faults please contact GARDENA Service.Repairs should only be carried out by GARDENA service centres or dealersauthorised by GARDENA.9. AccessoriesGARDENA Extension Cable Used to extend sensor cable to Art. 1186(length : 10 metres) max. 105 metres.GARDENA sensor tip For replacement of damaged Obtainable viawith felt sensor tip. GARDENA Service1835-28.960.02_12.03.2007.qxd 15.03.2007 15:38 Seite 12