Owner’s manual-40-FAILURE CAUSE SOLUTION15 The radiator fan does notwork.- The battery is not connected to thebike- The KEW SW swithc is in OFFposition.- The 5 A fuse for the assistantinstalation is blown.- The radiator fan is disconnected.- The radiator thermo-switch doesnot work.- Connect the battery 100% charged to the bike- Select at the KEY SW the position ON.- Replace the blown fuse by a new one with sameampers specification. If failure still there visit thetechnical service.- Connect the radiator fan to the assistant instalation ofthe bike.- Go to technical service.16 The motor does not work. - The battery is not connected to thebike- The KEW SW swithc is inOFF position.- The ON / OFF swithc is inOFF position.- The overboard device is not in place.- The throttle device is damaged &does not work..- Connect the battery 100% charged to the bike- Select at the KEY SW switch the position ON.- Select at the ON / OFF swith the position ON.- Fix in place the overboard device.- Go to technical service.17 The battery does not getcharged.- The charger is not charging- The charger is damaged.- The battery is damaged.- Connect the charger to the mains.- Go to technical service.- Go to technical service.Troubleshooting