66 Operating Manual BX920 S4Troubleshooting and tipsPower budget limit value exceededÊ Check whether the power budget limit value set in the management bladehas been exceeded. You may need to install an additional power supply unit.8.7 Hard disk drive error messages at systembootVarious hard disk drive error messages may appear when the system isrebooted. These error messages are caused by modifications in the selectedRAID configuration.RAID controller configuration incorrectÊ Check and correct the settings for the drives using the RAID controllerconfiguration program.Further information can be found in the operating manual for the RAIDcontroller.8.8 Added drive reported as defectiveRAID controller is not configured for this driveThe drive was probably installed when the system was switched off.Ê Reconfigure the RAID controller for the drive using the corresponding utility.Information is provided in the documentation for the RAID controller.8.9 Error message on screenThe meaning of the error message is explained in the documentation for therelevant components and programs on the Fujitsu manuals server. |