Command Specifications4-178 C141-C009(2) Logical/physical address conversionThis response data reports the execution results of address conversion specified inthe “Logical/Physical Address Conversion” parameter in the SENDDIAGNOSTIC command in bytes after byte 4. The format and contents of thisresponse data are shown in Table 4.118.Table 4.118 RECEIVE DIAGNOSTIC RESULTS response data: logical/physicaladdress conversionBitByte 7 6 5 4 3 2 1 00 X ‘40’ (Page Code)1 0 0 0 0 0 0 0 02 X ‘00’ (Page Parameter Length)3 X ‘0A’ (Page Parameter Length)4 0 0 0 0 0 Address Format Before Conversion5 0 0 0 0 0 Address Format After Conversion67 Logical or Physical Address13The value of the “Page Parameter Length” field in this response datais a variable length within the range of [2 + 8n] in the FCspecifications. For example, If multiple logical data blocks arelocated in 1 physical sector, or if 1 logical data block is located inmultiple physical sectors, n address information items are reportedas the address conversion results.In the current IDD specifications, multiple address informationitems are not reported in this response data, but the “Page parameterlength” always shows X ‘000A.’ However, considering expandedspecifications in the future, the INIT should make it possible tocorrespond to variable lengths for the “Page parameter length.”~~ ~~~~