4.1 Control/Sense CommandsC141-C009 4-55(8) Notch parameters (page code = 0C)Table 4.25 MODE SELECT parameters: notch parametersBitByte 7 6 5 4 3 2 1 00 0 0 0 0 1 1 0 01 X‘16’ (Page Length)2 ND LPN X‘00’ (Reserved)Default 0 0 0 0 0 0 0 0Variable 0 1 0 0 0 0 0 03 X‘00’ (Reserved)4-5 Maximum number of notchesDefault X‘0012’Variable X‘0000’6-7 Active NotchDefault X‘0000’Variable X‘FFFF’8-11 Starting BoundaryDefault X‘00000000’Variable X‘00000000’12-15 Ending BoundaryDefault X‘xxxxxxxx’Variable X‘00000000’16-23 Page NotchDefault X‘0000000000000008’Variable X‘0000000000000000’This page is used to report the top address and final address of each zone.If the zone number + 1 of the notching zone is set in the "Active notch" field andthis parameter is issued, the starting and ending address of the specified zone canbe referred to by the MODE SENSE command.Also, if Page 3 and Page 3F are specified by the MODE SENSE command, theparameters below the zone specified in the notch page can be referred to.• Track/zone (Page 3, Byte 02, 03) (Note)• Sector count/track (Page 3, Bytes 10, 11)• Track Skew Factor (Page 3, Bytes 16, 17)• Cylinder Skew Factor (Page 3, Bytes 18, 19)