3.2 Cleaning the ADFfi-5530C2 Image Scanner Operator’s Guide 93DAILY CARE3• Feed and Eject rollers1) Open the ADF when "P" or "0" is not indicated on the Function Number display.If you open the ADF when "P" or "0" is indicated on the Function Number display,the Feed/Eject rollers will not rotate even if you perform step 2) below.2) Simultaneously hold down the [Send to] and [Scan] buttons on the operator panel.The Feed/Eject rollers start rotating slowly.3) Put a soft cloth moistened with cleaning fluid to the surface of the rotating Feed/Eject rollers lightly so that the surface of the rollers is cleaned.As a guideline, seven presses of the [Send to] and [Scan] buttons make the Feed/Eject rollers to rotate one full turn.• Plastic rollersClean the Plastic rollers lightly, preventing scratches on the roller surfaces. Take particularcare in cleaning these rollers as black debris on them adversely affects the pickupperformance. Be careful not to damage the sponges beside the rollers.• Sheet guidesWipe clean lightly.• GlassWipe clean lightly.• Ultra sonic sensorWipe clean lightly with a dry cloth.