E024S 10 732642 - Rev. F7.1 SETTING THE BUS PHOTOCELLSImportant to give both the transmitter and thereceiver the same address.Make sure that there are not two or more pairsof photocells with the same address.If no BUS accessory is used, leave the BUS con-nector free (J10 - fig. 1).PAIR Dip1 Dip2 Dip3 Dip4 Ref. Type1 OFF OFF OFF OFFB -C OPENING2 OFF OFF OFF ON3 OFF OFF ON OFF4 OFF OFF ON ON5 OFF ON ON OFF6 OFF ON ON ON7 ON OFF OFF OFFD CLOSING8 ON OFF OFF ON9 ON OFF ON OFF10 ON OFF ON ON11 ON ON OFF OFF12 ON ON OFF ON13 ON ON ON OFF14 OFF ON OFF OFF A OPENINGand CLOSING15 OFF ON OFF ON16 ON ON ON ON / OPEN PULSETab. 3 - Setting of bus photocellsTable 3 shows the programming operations of the dip-switchinside the transmitter and of the BUS Photocells receiver.A maximum of 16 BUS photocell pairs can be connected tothe board.The photocells are split into groups:Opening photocells: max 6Closing photocells: max 7Opening /Closing photocells: max 2Photocell used as an OPEN pulse: max 1Fig. 2 shows a 2-swing leaf automated system indicating thecoverage beams of the photocells:A: Photocells with OPENING and CLOSING action.B: Photocells with OPENING actionC: Photocells with OPENING actionD: Photocells with CLOSING action6.3.5 RETURN TO DEFAULT SETTINGSRestore the default settings as follows:1. Keep the SETUP push-button pressed to switch the board ON.2. Both SETUP LEDs are alternately lit3. The board resets the parameters.4. Until the SETUP push-button is pressed, movements are inhibited.5. When the SETUP push-button is released, both LD4 and LD5LEDs flash.6. The default configuration is reset and the new Setup can bestarted.Fig. 26.3.6 PARAMETER DEFINITION- Anti-wind: the anti wind function enables the gate to operateeven if there are gusts of wind. The obstacle detection time isset to 5 s and commands the reversal of motion.- Reversing stroke: when the gate is closed, the reversing strokefunction makes it possible that before the opening movement,the motors push to close for approx. 3 s to facilitate uncouplingthe electric lock.- Soft-touch: the soft touch function makes it possible that, aftertouching the closing limit stop, the leaves reverse and thenrest gently. This function can be useful to observe the impactcurve as requested by current standards.- Pre-flashing: it activates approx. 3 s before every openingand closing movement- Leaf delay at opening: it delays the leaf 2 start at openingwith respect to leaf 1, avoiding thus any interference betweenthe leaves.- Leaf delay at closure: it delays leaf 1 at closure with respectto leaf 2.- Pause time: In logic A it is the time set for the leaf re-closureafter the opening.- Stop point search space: this parameter adjusts themechanical stop search angle within which the board stopsthe movement without reversing if an obstacle is encounteredor the mechanical stop itself can be adjusted.7 INSTALLATION OF BUS ACCESSORIESThis board is supplied with a BUS circuit enabling easy con-nection of a high number of BUS accessories (e.g. up to 16photocells pairs), appropriately programmed, using only twocable without polarity.Below we describe the addressing and memory storage ofthe BUS photocells.For other future accessories, refer to the specific instructions.ENGLISH