C12 Maintenance 3. CoversC Series Maintenance Manual Rev.2 4553.10 Base Maintenance CoverCAUTION■ When mounting the cover, be careful not to get the cables caught in it or bendthem forcibly to push into the cover.Unnecessary strain on cables may result in damage to the cables, disconnection,and/or contact failure. These are extremely hazardous and may result in electricshock and/or improper function of the robot system.When routing the cables, check the cable locations at removing the cover.Be sure to place the cables back to their original locations.Removal Remove the screws and then remove the basemaintenance cover.Cross recessed truss head small screws: 6-M4×10Installation Install the base maintenance cover to the Manipulator.Hexagon socket head cap bolts: 6-M4×10Tightening Torque: 0.9 ± 0.1 N·mBe careful not to get the cables caught between the cover and the Manipulator body.NOTE