C8 Maintenance 3. CoversC Series Maintenance Manual Rev.2 207Installation Insert the connectors.RJ45 connector:Insert the RJ45 connector to the connector on the cover.F-sensor connector:Insert the metallic connector to the connector on the cover.S, C models:Install the Arm #4 side cover to the Manipulator.Cross recessed truss head small screws: 7-M4×10 (one side)Tightening torque: 0.9 ± 0.1 N·mP model:Install the Arm #4 side gasket to the grove on theArm #4 side cover. Install the Arm #4 cover tothe Manipulator.Cross recessed truss head small screws:7-M4×12 (one side)Tightening torque: 4.0 ± 0.2 N·mBe careful not to get the gasket and cables caughtbetween the cover and the Manipulator.Replace the gasket if there are flaws ordeteriorations.When replacing the cover, attach the electricalshock warning label and other labels to the placesindicated in the photos.NOTE