PCBsRemoving the Folder Controller PCB■ Actions before Replacing the Parts● In case the host machine was able to store the adjustment values1. Before replacing the Folder Controller PCB, store the adjustment values and the counter of the consumable partsto the host machine from the service mode of the host machine.Service Mode > SORTER > FUNCTION > FLD-BK-R2. Turn OFF the main power switch to store the value.● In cases the host machine was not able to store the adjustment values1. Before replacing the Folder Controller PCB, output the service mode setting values P-PRINT.Service Mode > COPIER > FUNCTION > MISC-P > P-PRINT2. Turn OFF the main power switch■ Preparation1. Remove the rear upper cover. “Removing the Rear Upper Cover” on page 64■ Procedure1. Disconnect all connectors and remove one screw and three locking supports [1] to remove the folder controllerPCB.• All Connector• 1 Screw• 3 Locking Supports1x[1][1]■ Actions after Replacing the Parts1. Turn ON the main power switch.2. If a message prompting the user to update the version appears, press [Update] to update automatically the versionof this equipment.NOTE:If [Skip] is selected, a message prompting the user to update the version will appear every time when the host machine is started.It is possible to set not to display the message by the service mode (Level 2) shown below.Service Mode_COPIER > OPTION > FNC-SW > VER-CHNG4. Disassembly/Assembly86