Action on parts replacementActions when Replacing the Folder controller PCB■ Actions before Replacing the Parts● In case the host machine was able to store the adjustment values1. Before replacing the Folder Controller PCB, store the adjustment values and the counter of the consumable partsto the host machine from the service mode of the host machine.Service Mode > SORTER > FUNCTION > FLD-BK-R2. Turn OFF the main power switch to store the value.● In cases the host machine was not able to store the adjustment values1. Before replacing the Folder Controller PCB, output the service mode setting values P-PRINT.Service Mode > COPIER > FUNCTION > MISC-P > P-PRINT2. Turn OFF the main power switch■ Actions after Replacing the Parts1. Turn ON the main power switch.2. If a message prompting the user to update the version appears, press [Update] to update automatically the versionof this equipment.NOTE:If [Skip] is selected, a message prompting the user to update the version will appear every time when the host machine is started.It is possible to set not to display the message by the service mode (Level 2) shown below.Service Mode_COPIER > OPTION > FNC-SW > VER-CHNG● In case the host machine was able to store the adjustment values1. Write the adjustment values and the counter of the consumable parts to the new PCB from the service mode of thehost machine.Service Mode > SORTER > FUNCTION > FLD-BK-W2. Turn OFF/ ON the main power switch.● In case the host machine was not able to store the adjustment values1. Executing the following sensor adjustment.Service Mode > SORTER > FUNCTION > PF-SENS1Service Mode > SORTER > FUNCTION > PF-SENS2Service Mode > SORTER > FUNCTION > PF-SENS3Service Mode > SORTER > FUNCTION > PF-SENS45. Adjustment105