Reread DelayThis sets the time period before the scan engine can read the same barcode a second time.Setting a reread delay protects against accidental rereads of the same barcode. Longer delaysare effective in minimizing accidental rereads. Use shorter delays in applications whererepetitive barcode scanning is required. Reread Delay only works when in a PresentationMode(see page 30. Default = Medium.~ D L Y R R D 5 0 0 .Short(500ms)~ D L Y R R D 7 5 0 .「Medium(750ms)」~ D L Y R R D 1 0 0 0 .Long(1000ms)~ D L Y R R D 2 0 0 0 .Extra Long(2000ms)User-Specified Reread DelayIf you want to set your own length for the reread delay, scan the barcode below, then setthe delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, thenscanning Save.~ D L Y G R D .「User Specified Reread Delay」Example) When setting the prevention timer to 10 seconds, scan in the following order.「Identical code reading prevention custom timer」→「1」「0」「0」「0」「0」→「Confirm」2D Reread DelaySometimes 2D barcodes can take longer to read than other barcodes. If you wish to set aseparate Reread Delay for 2D barcodes, scan one of the programming codes that follows. 2DReread Delay Off indicates that the time set for Reread Delay is used for both 1D and 2Dbarcodes. Default = 2D Reread Delay Off.~ D L Y 2 R R 0 .「2D Reread Delay Off」