15MARTINA - VANESSA - ALESSIA - SOLARISEN9.4 GENERAL INSTALLATIONFig. 14 - General installationLEGEND Fig. 14 page 151 Stove2 Minimum lateral distance = 300 mm3 Minimum rear distance = 200 mm4 Minimum front distance = 1000 mm• Please check that the floor has an adequate load capacity. If the existing one does not satisfy this requirement,appropriate measure should be provided (for example a plate for distributing the load).• It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 300mm on the sides and 200 mm on the back, to enable an eficient appliance cooling and a good distributionof heat in the room (see Fig. 14 page 15).• For safety fire regulations the distances from flammable or sensible to heat objects (sofas, pieces of furniture,wooden covering, etc...) must be respected, has described in Fig. 14 page 15.• If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances must be furtherincreased with 1 meter.• If the walls are made up of flammable materials, check the safety distances (see Fig. 14 page 15).• At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessaryplease install a fire resistant plate on the concerned walls.• In some countries also masonring load-bearing walls are considered flammable.9.5 SIDE PANEL ASSEMBLY (MARTINA MODELS)Fig. 15 - Upper screws removal Fig. 16 - Backward screws removal• Remove the top cover: unscrew the 2 upper screws and the 3 backward screws (see Fig. 15 page 15 andFig. 16 page 15).