15WIRE THE ENTRAPMENT PROTECTION DEVICESWIRINGWIRE THE ENTRAPMENT PROTECTIONDEVICESAn entrapment protection device such as photoelectric sensors or an edge MUST bewired to the operator and then configured for your application. Refer to page 18 -page 21 for programming information.PHOTOELECTRIC SENSORSEntrapment protection devices are required.Input for UL325 compliant entrapment protection devices such as photoelectricsensors. Configure either CX, CY, or CZ (N.C.) contacts.NOTE: If not used deactivate the contacts using the programming menu.C1 “OPEN WHILE CLOSING” (N.C.) ContactIf the photoelectric sensor beam is blocked while the gate is closing, the gate will stopand reverse to the fully open position.C2 “CLOSE WHILE OPENING” (N.C.) ContactIf the photoelectric sensor beam is blocked while the gate is opening, the gate willstop and reverse to the fully closed position.C3 “PARTIAL STOP”(N.C.) ContactIf the photoelectric sensor beam is blocked while the gate is moving, the gate willstop and automatically shuts (if this function has been selected).C4 “STANDBY OBSTACLE” (N.C.) ContactIf the photoelectric sensor beam is blocked while the gate is moving, the gate willstop and once the obstruction is removed the gate will resume moving in the samedirection.DIR10 Photoelectric Sensors:RX TX