12 | Analog and Frequency Inputs66 / 144 Manual_C_80 Bosch MotorsportPhysical limitsof channelEnter physical limitsof the sensorChoose data typeof the measurementvariableEnable additionalonline calibrationEnter name to auto-matically create anew measurementsheet7. Click ‘Finish’ when done.8. Enter channel name and description.9. Click ‘OK’ when done.The channel is inserted into the C 80 Project Tree.Channel is linkedto ANA06Input pull-up resistoris deactivatedCharacteristiccurve for sensorAdjustmentis enabledAvailable measurements for channel:Measurement label Functionraw_name mV value of sensorraw_name_fi filtered mV value of sensorname physical value of sensorname_fi filtered physical valueOnline definition of the curve is covered in chapter ‘Online calibration of measurementchannels [} 80]’.NoteWorking with automatically created measurement sheets is explained in chapter ‘Settingup an online measurement [} 75]’.