Once your Art-Net server has been properly configured, create the matching inputs inthe Inputs Pane of the Programming workflow layout. Once these inputs have been definedand values are being sent, you can see the matching inputs display the updated valuesin X-Agora.Art-Net OutputsIn the Actions pane of the Programming workflow layout, you can drop Art-Net actionsonto your Timelines to send Art-Net messages to the specified address.8.2.2 Hog connectivityUsing Art-Net connectivity, X-Agora supports advanced control of your project, fromprogramming to playback, from a Hog system.8.3 CalibrationUse the Calibration window to calibrate individual projectors when on site. X-Agorafeatures five projection calibration tools, most of which can be used in conjunction witheach other. The documentation for each tool outlines the other calibration tool withwhich it should or should not be used. Projectors can be calibrated, while other displayscannot, and more than one projector can be calibrated at the same time.8.3.1 Calibration workflow1. Open the calibration window by means of a projector's right click menu,either in the Displays pane or in the Outputs layout, a projector'sproperties in the Outputs layout, or by means of a preset.2. Select from five different calibration tools: Reverse Mapping, EdgeWarping, Manual Blending, Warping, or Live Masking.Each of these tools can be turned on or off by using a check box. Thecalibration effect from those tools is applied in the order in which thetools are displayed.3. Click the Edit button corresponding to a tool, in the Options pane.When using a tool, the Viewport switches to display the image that isto be projected by the selected projector. The Options pane also showsmore calibration options that are not specific to a tool.Click Done when you are finished.Barco Pn: 60600320188Section 8: FeaturesBarco Media Server XHD-Series User Guide