ACURA’sRX210 User Manual Page 25 of 35Set RSSI Value CommandThis command will set the RSSI value and commit it to the Data EEPROM. It alsoinitiates an RF Module reset and writes the new value to the RF Module. Broadcastshere are useful to set all the readers to their most sensitive etc. The RSSI Valueranges from 0 to 255. 0 being the most sensitive.Command0xA 0x01 Network Receiver Node ID 0x07 New RSSI ChecksumResponse0x5 0x00 Network Receiver Node ID 0x07 ChecksumGet RSSI Value CommandThis command will return the RSSI value it is currently using, and defined in the DataEEPROM.Command0xA 0x00 Network Receiver Node ID 0x08 ChecksumResponse0X5 0x01 Network Receiver Node ID 0x08 RSSI ChecksumSet Site Code CommandThe Site Code or Site Code is a group of 3 bytes assigned to each tag. Its function isto enable the reader to filter out any tags that it receives that is not part of the site it ismonitoring. These values are committed to the Data EEPROM.When a Site Code of 0 value is assigned, then all the tags read are reported.Entering a separate code, will result in any tags other than those meeting this code tobe rejected by the reader.Command0xA 0x03 Network Receiver Node 0x0 Site Site 2 Site 3 ChecksumResponse0x5 0x00 Network Receiver Node ID 0x09 ChecksumGet Site Code CommandThis command will return the active Site Codes.Command0xA 0x00 Network Receiver Node 0x0A ChecksumResponse0x5 0x0 Network Receiver Node 0x0 Site Site 2 Site 3 Checksum