ACURA’sRX210 User Manual Page 22 of 350 No errors encountered1 Unknown reader command received2 Tag Table underflow error3 Command Packet checksum error4 RF Module - Unknown command response5 RF Module - Unknown general response6 RF Module - Re-sync failure7 RF Module - Command response failure8 RF Module - Receive response failure9 No response packet received from polled readerDisable Auto Polling CommandThe function of this command is to disable future Auto Polling after power up byresetting the Auto Polling flag in the Data EEPROM. This command can beaddressed directly to reader 1, or on a broadcast basis.Command0xA 0x00 Network Receiver Node ID 0x02 ChecksumResponse0x5 0x00 Network Receiver Node ID 0x02 ChecksumPing Reader CommandThe Ping Command is simply used to check if a reader is on the network andresponding correctly. It can be used to read back Network ID's, Reader ID's andNode ID's. Inserted into the response from a Ping Command is and Error Number.This number refers to the last error the respective reader has experienced. Onceread, this number is cleared.To clear all the errors on all the readers, simply broadcast a Ping Command.Command0xA 0x00 Network Receiver Node ID 0x03 ChecksumResponse0x5 0x01 Network Receiver Node ID 0x03 Error ChecksumError Numbers are as follows: