Installation Manual for digital sets - IP sets - SIP sets AMT/PTD/TR/0001/3/7/ENInstallation rules 05/2008 Page 12-312.2.3 To connect IP i7xx range setsIP sets are connected to the LAN using an RJ45 connector and a category 5 cable, with 2 RJ45connectors at each end. The cord is not supplied with the set.Set of 10 Ethernet cables: HT1455A.The set can operate in two Ethernet modes, 10 base T and 100 base TX.12.2.4 Power supply for i7xx range sets12.2.4.1 Introduction:Power can be supplied to i740, i760 and i780 sets in one of two ways:• Remote supply via Ethernet,• External power supply from a mains power supply unit (PN1120A for the i780 set, PN1121A forthe i760 set, and PN1121D for i740/i740N sets).If both supply methods are used, power will be supplied by the one that was connected first:• If the power supply unit is connected first, it supplies power to the set,• If the network cable that provides the remote power supply is connected before the powersupply unit, it supplies the set.12.2.4.2 Remote supply of i7xx range sets via the ethernet networkFor the connector positions, refer to the user guides and quick reference guides for each set.Attention :According to the manufacturer, remote supply distribution is different through the RJ45network connector.i740N set:These sets are compliant with standard IEEE802.3 af. Remote power supply is possible once theswitch to which is attached is in line with this standard.This standard comprises a classification according to the sets' consumption: the i740N setcorresponds to class 1.Other i7xx range sets:Two references are recommended:• CATALYST 3524 PWR XL (RJ45),• POWER DSINE 6024 (RJ45).