Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Overview of this manual
- Product documentation, M2000/M2000A
- Product documentation, M2004
- How to read the product manual
- Safety
- General safety information
- Safety in the manipulator system
- Safety risks
- CAUTION - Hot parts may cause burns
- Safety risks related to tools/work pieces
- Safety risks related to pneumatic/hydraulic systems
- Safety risks during operational disturbances
- Risks associated with live electric parts
- Safety actions
- Fire extinguishing
- Emergency release of the manipulator's arm
- Brake testing
- Risk of disabling function "Reduced speed 250 mm/s
- Safe use of the FlexPendant
- Work inside the manipulator's working range
- Signal lamp (optional)
- Safety stops
- Safety related instructions
- Safety symbols on manipulator labels
- DANGER - Moving manipulators are potentially lethal
- DANGER - First test run may cause injury or damage
- WARNING - The brake release buttons may be jammed after service work
- DANGER - Make sure that the main power has been switched off
- WARNING - The unit is sensitive to ESD
- WARNING - Safety risks during handling of batteries
- WARNING - Safety risks during work with gearbox lubricants (oil or grease)
- Installation and commissioning
- Robot transportation precautions
- Securing the robot
- Unpacking
- Working range, IRB 7600 - 150/3.5
- Working range, IRB 7600 - 340/2.8
- Working range, IRB 7600 - 400/2.55, IRB 7600 - 500/2.55
- Working range, IRB 7600 - 500/2.3
- Risk of tipping/stability
- On-site installation
- Lifting robot with lifting slings
- Lifting robot with roundslings
- Manually releasing the brakes
- Manually releasing the brakes, external brake release unit
- Lifting the base plate
- Securing the base plate
- Orienting and securing the robot
- Fitting equipment on robot
- Installation of base spacers (option)
- Extended working range, axis 1 (option 561-1)
- Installation of cooling fan for motors, axes 1-3 (option)
- Installation of Foundry Plus Cable guard (option no. 908-1)
- Loads
- Installation of signal lamp (option)
- Restricting the working range
- Mechanically restricting the working range of axis 1
- Mechanically restricting the working range of axis 2
- Mechanically restricting the working range of axis 3
- Installation of position switches (option)
- Electrical connections
- Maintenance
- Maintenance schedule and expected life
- Maintenance schedule
- Expected component life
- Inspection activities
- Inspection, oil level gearbox axis 2
- Inspection, oil level gearbox axis 3
- Inspection, oil level gearbox axis 4
- Inspection, oil level, gearbox axis 5
- Inspection, oil level gearbox axis 6
- Inspection, balancing device
- Inspection, cable harness
- Inspecting, mechanical stop pin, axis 1
- Inspection, mechanical stop, axes 1, 2 and 3
- Inspection, damper axes 2-5
- Inspection, position switch axes 1, 2 and 3
- Inspection, information labels
- Inspection, UL-lamp
- Changing/replacement activities
- Oil change, gearbox axis 1
- Changing oil, axis-2 gearbox
- Changing oil, axis-3 gearbox
- Oil change, gearbox, axis 4
- Oil change, gearbox, axis 5
- Oil change, gearbox axis 6
- Replacing the SMB battery
- Lubrication activities
- Cleaning, robot
- Lubrication of spherical roller bearing, balancing device
- Service Information System, M2000
- Description of Service Information System (SIS)
- SIS system parameters
- Setting the SIS parameters
- Reading the SIS output logs
- Exporting the SIS data
- Repair
- General procedures
- Mounting instructions for bearings
- Mounting instructions for seals
- Complete robot
- Replacement of cable harness, axes 5-6
- Replacement of complete arm system
- Upper and lower arm
- Replacement of complete wrist unit
- Replacement of complete upper arm
- Replacement of complete lower arm
- Replacement of lower arm shaft
- Frame and base
- Replacement of brake release unit
- Replacing the balancing device
- Replacement of spherical roller bearing, balancing device
- Unloading the balancing device using hydraulic press tool
- Restoring the balancing device using a hydraulic press tool
- Motors
- Replacement of motor axis 2
- Replacement of motor, axis 3
- Replacement of motor, axis 4
- Replacement of motor, axis 5
- Replacement of motor, axis 6
- Gearboxes
- Replacement of gearbox, axis 2
- Replacement of gearbox, axis 3
- Replacement of gearbox, axis 4
- Replacement of gearbox, axis 5
- Replacement of gearbox, axis 6
- Calibration information
- Calibration methods
- Calibration scale and correct axis position
- Calibration movement directions for all axes
- Updating revolution counters
- Checking the calibration position
- Decommissioning
- Decommissioning of balancing device
- Reference information
- Applicable safety standards
- Unit conversion
- Screw joints
- Weight specifications
- Standard tools
- Special tools
- Lifting accessories and lifting instructions
- Spare part / part list
- Spare parts
- Spare part list
- Part list
- Rebuilding parts
- Part list, overview
- Mechanical stop axis 1, 3HAC12812-2
- Base incl frame axis 1, 3HAC12304-1
- 8.3.6 Axis 3-4, 3HAC13063-1 (IRB 7600 - 150/3.5, - 325/3.1, -340/2.8, -400/2.55
- Axis 3-4, 3HAC13063-2 (IRB 7600 - 500/2.3)
- 8.3.8 Axis 3-4, Foundry, 3HAC13063-4 (IRB 7600 -150/3.5, - 325/3.1, - 340/2.8, - 400/2.55
- Axis 3-4 Foundry, 3HAC13063-5 (IRB 7600 - 500/2.3)
- Wrist, 3HAC16628-4 / 3HAC16628-3
- Material set robot, 3HAC13079-1
- Material set axis 1-2, 3HAC13077-1
- Material set balancing device, 3HAC13082-1
- Arm extension set, 956 mm, 3HAC12311-1 (IRB 7600 - 150/3.5)
- Arm extension set, 250 mm, 3HAC12311-2 (IRB 7600 - 340/2,8)
- Exploded views
- Base incl. Frame
- Frame-Lower arm 1
- Frame-Lower arm 2
- Upper arm
- Wrist complete
- Circuit diagram
- Validity of circuit diagram 3HAC025744-1
- Validity of circuit diagram 3HAC13347-1
- Index
|
NoteArt. no.Equipment, etc.A new friction washer must alwaysbe used when refitting the wristunit.3HAC11755-1Friction washer3HAC12734-1Lifting tool, wrist unitContent is defined in sectionStandard tools on page 411.-Standard toolkitComplete kit that also includes op-erating manual.3HAC15716-1Calibration Pendulum toolkitThese procedures include refer-ences to the tools required.Other tools and procedures maybe required. See references tothese procedures in the step-by-step instructions below.See chapter Circuit diagram onpage 457.-Circuit diagramRemoval, wrist unitThe procedure below details how to remove the complete wrist unit.NoteActionDANGERTurn off all:• electric power supply to the robot• hydraulic pressure supply to the robot• air pressure supply to the robotBefore entering the robot working area.1Remove all equipment fitted to the turning disk.2Shown in the figure Location ofwrist unit on page 262.Turn axis 4 to a position where the cover, axis 5faces upwards.3Remove the cover, axis 5, by unscrewing its attach-ment screws.4CAUTIONThe complete wrist unit weighs 200 kg! All liftingequipment used must be sized accordingly!5Art. no. is specified in Requiredequipment on page 262.Fit the lifting tool, wrist unit to the two holes on thesealing surface against the cover, axis 5.6If required, cut any cable tiessecuring the cables in order tofit the tool.Shown in the figure Location ofwrist unit on page 262.Remove the rear cover by unscrewing its attach-ments.7Shown in the figure Location ofwrist unit on page 262.Disconnect connector R2.M5/6 at the rear cable divi-sion point.8Do not remove the attachmentsfrom the cabling!Remove all cable attachment inside the upper armand at the rear of the robot.9Slightly raise the wrist unit to unload the screw joint,facilitating removal of the attachment screws.10Continues on next page3HAC022033-001 Revision: M 263© Copyright 2007-2013 ABB. All rights reserved.4 Repair4.4.2 Replacement of complete wrist unitContinued
PreviousNext |