Endura AZ30 series integral probe and remote transmitterCombustion oxygen monitor 13 Transmitter Specification104 COI/AZ30E–EN Rev. D13 Transmitter SpecificationHazardous Area CertificationsTransmitterRemote Terminal HousingTransmitter EnclosuresRemote transmitter (mounted to remote terminal housing):Wall-, pipe- or stand-mounted (mounting bracket supplied)Integral transmitter:Head-mounted to probePhysicalRemote transmitter:Aluminium (EN AC44200 or 47000)Remote terminal housing:316L stainless steelIntegral transmitter:Aluminium transmitter housing / stainless steel probe and terminal housingII 2 GDEx d IIB +H2 Gb (Ta –20 to 55 °C)Ex tb IIIC T 85 °C Db IP66 (Ta –20 to 55 °C) IP66Certified ComponentIECEx BAS12.0050UBaseefa12ATEX0078UClass I Division 1 Groups BCD T6Class I Zone 1 AEx/Ex d IIB+H2 T6Class II Division 1 Groups EFG T6 (Ta –20 to 55 °C) Type 4XFM Certificate No. 3039243Max Current 1.2 AII 2 GDEx d IIB +H2 T6 Gb ( Ta –20 to 70 °C)Ex tb IIIC T85°C Db (Ta –20 to 70 °C) IP66Cert. No IECEx BAS12.0049XAtex Cert No. Baseefa12ATEX0077XClass I Division 1 Groups BCD T6Class I Zone 1 AEx/Ex d IIB+H2 T6Class II Division 1 Groups EFG T6 (Ta –20 to 55 °C) Type 4XFM Certificate No. 3039243