Cambium Networks PTP 670 Series manuals
PTP 670 Series
Brand: Cambium Networks | Category: Wireless Access Point
Table of contents
- user guide
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- general information
- Chapter 1: Introduction to synchronization
- Interference and reliability
- Sources of interference
- Neutralizing interference
- Configuration options for TDD synchronization
- Alternative to GPS synchronization
- Cambium's synchronization solutions
- CMM5
- CMM4 (Cabinet with switch)
- CMMmicro (CMM3) – Product is End of Life and no longer available for new shipments
- Product Overview
- Cluster Management: Scenario 2
- CMM5 Controller Module
- CMM5 Injector Module
- CMM5 Specifications
- Watt Power Supply
- Power Supply Selection (When to use Each One)
- Ferrite Beads
- Providing Sync to CMM5 via uGPS Module
- CMM5 Planning
- CMM5 Injector Initial Startup
- CMM5 Controller Initial Startup
- CMM5 Controller Configuration
- View System Status
- View Network -Interface Status
- View Synchronization Status
- View Chassis Status
- Identify a Chassis
- View Port Status
- View/Configure Static Routes
- Set Local Time/NTP Protocol
- Update Injector Firmware
- Update Controller Firmware
- Installing the CMM5
- Conforming to Regulations
- Installing a uGPS Antenna
- Figure 15 Installing a Single Controller
- Installing a Single Injector
- Installing Two Injectors side by side
- Figure 17: Two Injectors with Joining Bar
- Installing a Controller/Injector side by side
- Installing a 600 Watt Power Supply
- Figure 20: 600 Watt Power Supply Installation
- Figure 21: 600 Watt Power Supply Installation (rear view)
- Installing a Split DC Power Line
- Cabling the CMM5
- Figure 23: Wiring the Power Connector
- Class A Emissions Requirements
- CMM4 and Controller Board
- Figure 24 CMM4 internal view, including cable glands
- Figure 25 Rackmount CMM4
- Figure 26 GPS Antenna
- Power
- Ethernet Switch
- Specifications
- Table 4 Rackmount CMM4 specifications
- Providing sync to CMM via UGPS Module
- CMM Planning
- Figure 27 CMM4 Standard Configuration
- Figure 29 CMM4 cabled to use Gigabit Ethernet feed
- Figure 30 CMM4 cabled to support PTP 500/600
- Power Planning
- Syncing Two Co-located CMMs Together
- Cables
- Figure 31 Location of pin 1
- Table 9 Wire size for CMM4 DC cable
- Figure 32 CMM sync cable pinout
- EtherWAN Switch Information
- Configuring a CMM4
- Overriding Forgotten IP Addresses, Usernames, or Passwords
- Figure 35 Login page of CMM4
- User Update
- Add User
- Delete User
- Configuring General CMM4 Parameters
- Table 16 CMM tab attributes
- Configuring the SNMP parameters
- Figure 41 SNMP tab of CMM4
- Table 18 SNMP tab attributes
- Configuring VLAN
- Configuring the Unit Settings
- Viewing the ARP Table (Statistics)
- Viewing General Status
- Table 22 General Status tab attributes
- Viewing Sync Status
- Viewing the System Log
- Viewing the Network Interface
- Installing a CMM4
- Figure 50 Detail of GPS antenna mounting
- Figure 51 Weatherproofing an N-type antenna connector
- Figure 52 AP/BHM to UGPS cable
- Installing the power supply for the CMM4 (30 VDC or 54 VDC)
- Figure 54 Power supply AC connection
- Figure 55 CMM4 line filter installation (EU only)
- Figure 56 Rackmount CMM line filter installation (EU only)
- Temperature Range
- Figure 58 CMM4 V-bracket to pole mounting
- Installing a Rackmount CMM4 (Model 1092HH)
- Cabling a CMM4 (Models 1090CKHH and 1091HH)
- Figure 61 Ethernet port connections
- Figure 63 CMM4 LED indicators
- Cabling a Rackmount CMM4
- Figure 64 LED indicators - rackmount CMM4
- Power Faults
- Chapter 4: Universal Global Positioning System Module
- UGPS Product Description and Overview
- Figure 66 UGPS connector interface
- UGPS Power Source Configurations
- Figure 68 PMP 100 AP receiving synchronization from external-powered UGPS
- Figure 69 PMP 320 receiving synchronization from external-powered UGPS
- Figure 70 One PMP 400/430 AP and one PMP 100 AP receiving synchronization from external-powered UGPS
- Power from the Radio via UGPS Timing Port 1 or UGPS Timing Port 2
- Figure 72 AP/BHM to UGPS cable
- Figure 73 PTP 230 backhaul master powering UGPS and receiving synchronization
- Figure 74 PMP 450 AP powering UGPS and receiving synchronization
- Figure 75 Two PTP 230 backhaul master units powering UGPS and receiving synchronization
- Figure 76 PTP 230 backhaul master powering UGPS/receiving synchronization and PMP 100/430 receiving synchronization
- UGPS and CMM Configurations
- Product Specifications
- UGPS installation and operation
- Figure 77 UGPS to CMM cable pin configuration
- UGPS Installation Procedure
- Figure 82 CMM port conifguration for UGPS power
- IP default bypass
- Figure 83 IP default bypass - default radio on timing port 1
- Figure 84 IP default bypass - default radio on timing port 2
- GPS status and location data readout
- Retrieving GPS status and location data via SNMP
- Table 31 GPS SNMP OIDs - PMP 100/400/430 and PTP 100/200/230 series
- Table 32 GPS SNMP OIDs - PMP 320 series
- UGPS Power Port and Timing Port Pinouts
- Chapter 5: CMM Regulatory and Legal Notices
- National and Regional Regulatory Notices
- Equipment Disposal
- Table 35 Disclosure Table for China
- RF Exposure Separation Distances
- Legal Notices
- Hardware Warranty in U.S
- IMPORTANT NOTE ON MODIFICATIONS
PTP 670 Series
Brand: Cambium Networks | Category: Network Router
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- ENGLISH (UK, IE, NO)
- intended use
- Simplified EU Declaration of Conformity
- rf exposure near the antenna
- Equipment manufacturer
- typical installations
- ODU VARIANTS AND MOUNTING BRACKET OPTIONS
- INSTALLING THE ODU AND TOP LPU
- Mount the top LPU
- Install external antennas for a Connectorized ODU
- INSTALLING THE COPPER CAT5E ETHERNET INTERFACE
- Install the main drop cable
- Install the bottom LPU to PSU drop cable
- Test resistance in the drop cable
- INSTALLING THE PSU
- logging into the web interface
- Update the License Key and configure the ODU
- CZECH (CS)
- POZNÁMKY
- Zjednodušené prohlášení o shod pro EU
- Výrobce za ízení
- TYPICKÉ ZP SOBY INSTALACE
- VARIANTY VENKOVNÍ JEDNOTKY A DOSTUPNÉ MONTÁŽNÍ DRŽÁKY
- INSTALACE VENKOVNÍ JEDNOTKY A HORNÍ P EP OVÉ OCHRANY
- Upevn ní horní p ep ové ochrany
- Upevn ní externích antén pro venkovní jednotku s konektorem
- P IPOJENÍ M D NÉHO ETHERNETOVÉHO ROZHRANÍ CAT5E
- P ipojení hlavního p ipojovacího kabelu
- Upevn ní p ipojovacího kabelu mezi spodní p ep ovou ochranou a napájecím zdroje
- Zm ení odporu p ipojovacího kabelu
- INSTALACE NAPÁJECÍHO ZDROJE
- NASTAVENÍ VENKOVNÍ JEDNOTKY K PROVOZU V EU
- Aktualizace licen ního klí e a nastavení venkovní jednotky
- FRENCH (FR)
- REMARQUES
- Déclaration de conformité de l'UE simplifiée
- Fabricant de l'équipement
- INSTALLATIONS TYPIQUES
- VARIANTES D'ODU ET OPTIONS DE MONTAGE SUR SUPPORT
- INSTALLATION DE L'ODU ET DE LA LPU SUPÉRIEURE
- Montage de la LPU supérieure
- Installation des antenne externes pour une ODU connectée
- INSTALLATION DE L'INTERFACE CUIVRE ETHERNET CAT. 5E
- Installer le câble de liaison principal
- Installer le câble de liaison de la LPU inférieure à la PSU
- Tester la résistance dans le câble de liaison
- INSTALLATION DE LA PSU
- CONFIGURATION DE L'ODU POUR EXPLOITATION DANS L'UE
- Connexion à l'interface web
- SPANISH (ES)
- AVISOS
- Declaración de conformidad simplificada de la UE
- Fabricante del equipo
- INSTALACIONES TÍPICAS
- VARIANTES DE ODU Y OPCIONES DE SOPORTE DE MONTAJE
- INSTALACIÓN DE LA ODU Y LA LPU SUPERIOR
- Montaje de la LPU superior
- Instalación de antenas externas para una ODU conectorizada
- INSTALACIÓN DE LA INTERFAZ DE COBRE ETHERNET CAT5E
- Instalación del cable de bajada principal
- Instalación del cable de bajada de la LPU inferior a la fuente de alimentación
- Comprobación de resistencia en el cable de bajada
- INSTALACIÓN DE LA FUENTE DE ALIMENTACIÓN
- CONFIGURACIÓN DE LA ODU PARA OPERACIÓN EN LA UE
- Inicio de sesión en la interfaz web
- ITALIAN (IT)
- AVVISI
- Dichiarazione di conformità UE semplificata
- Produttore delle apparecchiature
- INSTALLAZIONI TIPICHE
- VARIANTI ODU E OPZIONI DI MONTAGGIO CON TRAVERSINO
- INSTALLAZIONE DI ODU E LPU SUPERIORE
- Montare la LPU superiore
- Installare antenne esterne per un'ODU connettorizzata
- INSTALLAZIONE DELL'INTERFACCIA ETHERNET CAT5E IN RAME
- Installare il cavo di discesa principale
- Installare il cavo di discesa dalla LPU inferiore alla PSU
- Verificare la resistenza nel cavo di discesa
- INSTALLAZIONE DELLA PSU
- CONFIGURAZIONE DELL'ODU PER IL FUNZIONAMENTO NELL'UE
- Aggiornare il codice di licenza e configurare l'ODU
- POLISH (PL)
- INFORMACJE
- Uproszczona deklaracja zgodno ci UE
- Bezpiecze stwo
- Producent urz dzenia
- TYPOWA INSTALACJA
- WARIANTY ODU I OPCJE KLAMRY MONTA OWEJ
- MONTA ODU I GÓRNEGO LPU
- Monta górnych LPU
- Monta zewn trznych anten do ODU ze zł czem anteny zewn trznej
- MONTA ZŁ CZA KABLA MIEDZIANEGO CAT5E ETHERNET
- Monta głównego kabla doł czeniowego
- Monta kabla doł czeniowego mi dzy dolnym LPU a zasilaczem
- Testowanie rezystancji w kablu doł czeniowym
- MONTA ZASILACZA
- Logowanie do interfejsu w przegl darce internetowej
- TURKISH (TR)
- Bu Hızlı Ba langıç Kılavuzu Hakkında
- Basitle tirilmi AB Uygunluk Beyanı
- Ekipman üreticisi
- TIPIK KURULUMLAR
- Topraklama kablolarını Dı Mekan Ünitesine takın
- En Üstteki Paratoner Ünitesini Monte Etme
- Konektörlü Dı Mekan Ünitesi için harici antenleri kurma
- Dı Mekan Ünitesi'ni en üstteki Paratoner Ünitesi saplama kablosuna takma
- Ana saplama kablosunu takma
- En alttaki Paratoner Ünitesini Güç Kayna ı Ünitesi saplama kablosuna takma
- Saplama kablosundaki direnci test etme
- AC Güç Enjektörünü Kurma
- Ülkeye özel Lisans Anahtarı olu turma
- Web arayüzüne giri
- HUNGARIAN (HU)
- EL ZETES INFORMÁCIÓK
- Egyszer sített EU-s megfelel ségi nyilatkozat
- Személybiztonság
- Berendezésgyártó
- JELLEMZ ELRENDEZÉSEK
- A KÜLTÉRI EGYSÉG VÁLTOZATAI ÉS A RÖGZÍT ELEM-VÁLASZTÉK
- A KÜLTÉRI EGYSÉG ÉS A FELS VILLÁMVÉDELMI EGYSÉG TELEPÍTÉSE
- A fels villámvédelmi egység felszerelése
- Küls antennák telepítése csatlakozóval ellátott kültéri egységhez
- A RÉZ CAT5E ETHERNET INTERFÉSZ TELEPÍTÉSE
- A f beköt kábel beszerelése
- Az alsó LPU és a tápegység közötti beköt kábel beszerelése
- A beköt kábelben lév ellenállás tesztelése
- A TÁPEGYSÉG TELEPÍTÉSE
- A KÜLTÉRI EGYSÉG KONFIGURÁLÁSA EU-BELI ÜZEMELTETÉSRE
- A licenckulcs frissítése a kültéri egység konfigurálása