Fujitsu PRIMERGY CX400 M4 manuals
PRIMERGY CX400 M4
Table of contents
- server enclosure
- copyright and trademarks
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- Notational conventions
- Before you start
- Classification of procedures
- Upgrade and Repair Units (URU)
- Field Replaceable Units (FRU)
- Average task duration
- Tools you need at hand
- Documents you need at hand
- Documents for the server enclosure
- Documents for the server nodes
- Important information
- ENERGY STAR
- Environmental protection
- Basic hardware procedures
- Determining the error class
- Global Error indicator
- Shutting down the server node
- Disconnecting the power cord
- Extending/removing the server enclosure out of the rack
- Extending the server enclosure out of the rack
- Removing server nodes from the server enclosure
- Removing the CX2570 M4 server node
- Removing the server node dummy module
- Opening the server enclosure
- Opening the midplane cover
- Installing the midplane cover
- Installing the fan cover
- Installing the server node dummy module
- Installing the server node in the server enclosure
- Installing the CX2550 M4/CX2560 M4 server node
- Installing the CX2570 M4 server node
- Mounting the server enclosure in the rack
- Attaching the carrier rails to the server enclosure
- Installing the carrier rails
- Lift the server into the rack cabinet
- Installing the cable management arm (CMA)
- Connecting the power cord
- Switching on the server node(s)
- Basic software procedures
- Completing the maintenance task
- Verifying system information backup / restore
- Using the Chassis ID Prom Tool
- Viewing and clearing the System Event Log (SEL)
- Clearing the SEL
- Performing a fan test
- Updating ServerView RAID Manager
- Power supply unit (PSU)
- General equipping rules
- Replacing the hot-plug PSU
- Removing the hot-plug PSU
- Installing the hot-plug PSU
- Concluding steps
- Removing and installing the PSU dummy module
- Installing the PSU dummy module
- Hard disk drives (HDD), solid state drives (SSD) and 2.5-inch PCIe-SSD
- Basic information
- HDD/SSD install order
- HDD/SSD backplane types
- HDD/SSD cage bezels
- Installing 2.5-inch HDD/SSD modules
- Removing a 2.5-inch HDD/SSD dummy module
- Installing a 2.5-inch HDD/SSD module
- Removing 2.5-inch HDD/SSD modules
- Removing a 2.5-inch HDD/SSD module
- Installing a 2.5-inch HDD/SSD dummy module
- Replacing a 2.5-inch HDD/SSD module
- Preliminary steps
- Replacing the 2.5-inch HDD/SSD SAS/SATA backplane
- Removing the fan modules cage
- Removing the 2.5-inch HDD/SSD backplane
- Installing the 2.5-inch HDD/SSD backplane
- Installing the fan modules cage
- Installing the HDD/SSD bridge board
- Replacing the HDD/SSD bridge board
- Removing the HDD/SSD bridge board
- Changing HDD/SSD cage bezels
- Removing the HDD/SSD x6 front bezel
- Removing the HDD/SSD x6 front bezel (screw type)
- Removing the HDD/SSD x4 front bezel
- Installing the HDD/SSD x6 front bezel
- Installing the HDD/SSD x4 front bezel
- System fan module
- Replacing the system fan module
- Removing the fan module
- Installing the fan module
- Replacing the fan cable
- Disconnecting the fan cable
- Connecting the fan cable
- Midplane kit
- Replacing the midplane kit
- Removing the midplane kit
- Installing the midplane kit
- Front panel
- Replacing the left front panel
- Removing the front panel
- Installing the front panel
- Replacing the right front panel
- Replacing the left front panel cable
- Removing the front panel cable
- Installing the front panel cable
- Replacing the right front panel cable
- Cabling
- Appendix
- Rear overview with CX2550 M4 / CX2560 M4 server nodes
- Rear overview with CX2570 M4 server nodes
- Enclosure interior
- Controls and indicators
- Indicators on the front panel (enclosure-related)
- Indicators on the front panel (node-related)
- ID card
- Indicators on the HDDs
- Indicator on hot-plug PSU
- Fan indicators
- Minimum startup configuration
PRIMERGY CX400 M4
Table of contents
- server enclosure
- copyright and trademarks
- Table Of Contents
- Table Of Contents
- Introduction
- Documentation overview
- Notational conventions
- Functional overview
- Server enclosure specification
- Installation steps, overview
- Important information
- ENERGY STAR
- FCC Class A Compliance Statement
- Environmental protection
- Transporting the server enclosure
- Notes on installing the server enclosure in the rack
- Hardware installation
- Unpacking the server enclosure
- Installing/removing the server enclosure in/from the rack
- Mounting the server enclosure in the rack
- Removing the server enclosure out of the rack
- Connecting the server enclosure to the mains
- Notes on connecting/disconnecting cables
- Starting up and operation
- Front overview with CX2560 M4 / CX2570 M4 server nodes
- Rear overview with CX2550 M4 or CX2560 M4 server nodes
- Rear overview with CX2570 M4 server nodes
- Controls and indicators
- Indicators on the front panel (enclosure-related)
- Indicators on the front panel (node-related)
- ID card
- Indicators on the HDDs
- Indicator on hot-plug PSU
- Switching the multi-node server system on and off
- Cleaning the server enclosure
- Property and data protection
- Troubleshooting and tips
- Drives reported as "dead" when starting system