Fujitsu PRIMERGY CX400 S1 manuals
PRIMERGY CX400 S1
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- Where to find which information
- Notational conventions
- Before you start
- Classification of procedures
- Field Replaceable Units (FRU)
- Average task duration
- Tools you need at hand
- For the 3.5-inch chassis
- Documents you need at hand
- Documents for the server enclosure
- Documents for the server nodes
- Important information
- CE conformity
- FCC Class A Compliance Statement
- Environmental protection
- Basic hardware procedures
- Disconnecting the power cord
- Removing the server enclosure out of the rack
- Removing the rear fixing brackets
- Removing the server node from the server enclosure
- Removing the server node CX270 S1
- Removing the server node dummy module
- Opening the server enclosure
- Removing the top cover 2
- inch chassis
- Removing the power distribution module
- Installing the power distribution module
- Closing the server enclosure
- Installing the top cover 1
- Installing the top cover
- Installing the server node dummy module
- Installing the server node in the server enclosure
- Installing server node CX250 S1
- Mounting the server enclosure in the rack
- Installing the rail kit cage nut
- Connecting the power cord
- Switching on the server node(s)
- Basic software procedures
- Performing a RAID array rebuild
- Power supply
- General equipping rules
- Required tools
- Installing the power supply module
- Concluding steps
- Removing the power supply module
- Installing the dummy cover
- Replacing the power supply module
- Removing the defective power supply module
- Replacing the power distribution board
- Removing the top PDB
- Installing the top PDB
- Replacing the defective bottom PDB
- Removing the bottom PDB
- Installing the bottom PDB
- Hard disk drives / solid state drives
- Basic information
- inch hard disk drives / solid state drives
- Configuration with standard CPU
- Installing 2.5-inch HDD/SSD modules
- Removing a 2.5-inch HDD/SSD tray
- Installing a 2.5-inch HDD/SSD module
- Removing 2.5-inch HDD/SSD modules
- Removing a 2.5-inch HDD/SSD module
- Installing a 2.5-inch HDD/SSD tray
- Replacing a 2.5-inch HDD/SSD module
- inch hard disk drives
- Installing 3.5-inch HDD modules
- Removing a 3.5-inch HDD tray
- Installing a 3.5-inch HDD module
- Removing 3.5-inch HDD modules
- Removing a 3.5-inch HDD module
- Installing a 3.5-inch HDD tray
- Replacing a 3.5-inch HDD module
- Replacing HDD/SSD SAS/SATA backplanes
- Removing the 2.5-inch HDD SAS/SATA backplane
- Installing the 2.5-inch HDD SAS/SATA backplane
- Replacing the 3.5-inch HDD SAS/SATA backplane
- Removing the 3.5-inch HDD SAS / SATA backplane
- Installing the 3.5-inch HDD SAS/SATA backplane
- System fan
- Replacing the fan in the fan module
- Removing the fan module
- Removing the fan from the fan holder
- Installing fan1 and fan2
- Installing the fan1
- Installing the fan2
- Installing fan3 and fan4
- Installing the fan4
- Installing the fan3
- Installing the fan module
- Midplane
- Replacing the midplane
- Removing the midplane
- Installing the midplane
- Linking boards
- Replacing the linking board
- Preliminary steps
- Installing the linking board
- Linking boards in 3.5-inch HDD chassis
- Removing the linking board
- Front panel
- Replacing the front panel board
- Removing the front ear bracket
- Removing the front panel board
- Installing the front panel board
- Installing the front ear bracket
- Replacing the front panel cable
- Removing the front panel cable
- Installing the front panel cable
- Routing of the front panel cable
- Cabling
- Connectors on the boards
- Appendix
- Multi-node server system front 3.5 inch HDD model
- Multi-node server system rear
- CX400 S1 server enclosure with CX270 S1 server nodes
- Multi-node server system interior
- inch HDD model
- Controls and indicators
- Controls on the front panel
- Hard disk drives
- Power supply module
- Minimum startup configuration