Fujitsu MAU3036RC SERIES manuals
MAU3036RC SERIES
Table of contents
- revision history
- CHAPTER 5 Sense Data and Error Recovery Methods
- conventions used in this manual
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- CHAPTER 1 SAS Interface
- Topologies in SAS Interface
- SAS Layering
- Physical links and phys
- Figure 1.4 Ports (narrow ports and wide ports)
- SAS devices
- Pathways
- Connections
- Names and identifiers
- Hashed SAS address
- Phy layer
- Link reset sequence
- Start conditions of the link reset sequence
- Figure 1.8 OOB signal transmission
- Table 1.6 OOB signal receiver burst time detection requirements
- SAS OOB sequency
- Figure 1.10 SAS to SAS OOB sequence
- Exception handling in the OOB sequence
- Figure 1.11 SAS speed negotiation window
- Figure 1.12 SAS speed negotiation sequence (Example 1)
- Phy reset sequence after devices are attached
- When the speed negotiation sequence is successful
- Link layer
- Table 1.11 Primitives used only inside SSP and SMP connections
- Primitive sequences
- BREAK
- CLOSE
- NOTIFY
- Table 1.13 OPEN_REJECT abandon primitives
- Table 1.14 OPEN_REJECT retry primitives
- SOAF (Start of address frame)
- Primitives used only inside SSP and SMP connections
- Table 1.15 DONE primitives
- EOF (End of frame)
- Clock skew management
- Scrambling
- Address frames
- IDENTIFY address frame
- OPEN address frame
- Table 1.23 CONNECTION RATE field
- Table 1.24 ARBITRATION WAIT TIME field
- Identification and hard reset sequence
- Connections overview
- Connection responses
- Table 1.26 Arbitration priority for OPEN address frames passing on a physical link
- Aborting a connection request
- Closing a connection
- Breaking a connection
- SSP link layer
- SSP frame transmission and reception
- Table 1.31 SSP frame interlock requirements
- Figure 1.17 Interlocked frames
- Closing an SSP connection
- Figure 1.20 Closing an SSP connection example
- Transport layer
- Table 1.33 FRAME TYPE field
- Information units
- Table 1.35 TASK ATTRIBUTE field
- TASK information unit
- Table 1.37 TASK MANAGEMENT FUNCTION field
- XFER_RDY information unit
- Figure 1.21 Example of XFER_RDY frames
- DATA information unit
- RESPONSE information unit
- Table 1.43 RESPONSE DATA field
- Sequences of SSP frames
- Figure 1.23 Example of write command
- Figure 1.25 Example of bidirectional command
- Exceptional event processing of a drive
- Figure 1.26 Example of the processing sequence for an exceptional event
- Table 1.45 Exceptional event processing of a drive
- CHAPTER 2 Command Processing
- Table 2.1 6-Byte CDB basic format
- Table 2.3 12-Byte CDB basic format
- Table 2.5 Control byte
- Status Byte
- Command Queuing Function
- UNIT ATTENTION Condition
- Response and release condition at UNIT ATTENTION condition hold state
- UNIT ATTENTION condition multiple hold
- Power Condition
- LED Display
- Illegal LUN specification
- Error recovery processing
- Abort processing
- Table 2.10 Reset processing during write
- Fatal hardware errors
- Figure 2.1 Data space configuration
- Logical block addressing
- CHAPTER 3 Data Buffer Management
- Figure 3.1 Data buffer configuration (in the case of 8 cache segments)
- Look-Ahead Cache Feature
- Caching parameters
- Look-Ahead operation, Look-Ahead volume
- CHAPTER 4 Command Specifications
- INQUIRY (12)
- Table 4.1 Standard INQUIRY data
- Table 4.2 VERSION field
- Table 4.3 Command queuing
- Table 4.4 Version descriptor
- Table 4.5 Command support data
- Table 4.6 Support
- Table 4.7 VPD information
- Table 4.9 VPD information: device serial No
- Table 4.10 VPD information: device unique information
- Table 4.11 VPD information: operation mode
- READ CAPACITY (25)
- MODE SELECT (15)
- Figure 4.1 MODE SELECT parameter structure
- Table 4.13 MODE SELECT command (Group 0) parameter configuration
- Table 4.14 MODE SELECT parameters
- Table 4.15 MODE SELECT parameters: read/write error recovery parameters
- Table 4.16 Combination of error recovery flags
- Table 4.17 MODE SELECT parameters: disconnect/reconnect parameters
- Table 4.18 MODE SELECT parameters: format parameters
- Table 4.19 MODE SELECT parameters: drive parameters
- Table 4.20 MODE SELECT parameters: verify error recovery parameters
- Table 4.21 MODE SELECT parameters: caching parameters
- Table 4.22 MODE SELECT parameters: control mode parameters
- Table 4.23 TST
- Table 4.24 QErr
- Table 4.25 MODE SELECT parameters: notch parameters
- Table 4.27 Port control parameter: Sub Page Format (Long Format)
- Table 4.28 SAS phy mode descriptor format
- Table 4.29 Power condition parameter: Page 0 Format (Short Page Format)
- Table 4.30 MODE SELECT parameters: informational exception control page
- Table 4.31 MRIE
- Table 4.32 Interval timer
- Table 4.33 MODE SELECT parameters: additional error recovery parameters
- MODE SELECT EXTENDED (55)
- MODE SENSE (1A)
- Table 4.35 Mode page
- Table 4.36 MODE SENSE data type specifications
- Table 4.37 MODE SENSE command (group 0) parameter configuration
- MODE SENSE EXTENDED (5A)
- Table 4.38 MODE SENSE EXTENDED command (group 2 parameter configuration
- REZERO UNIT (01)
- RESERVE (16)
- RESERVE EXTENDED (56)
- RELEASE (17)
- RELEASE EXTENDED (57)
- LOG SELECT (4C)
- Table 4.39 PC (page control)
- Table 4.41 Page code
- LOG SENSE (4D)
- Table 4.43 "Page Code" assignment for the log pages
- Table 4.44 Support log page (X'00')
- Table 4.45 Buffer overrun/underrun page (X'01')
- Table 4.46 Write error count page (X'02')
- Table 4.49 Total write errors posted (page 02, code 0002)
- Table 4.51 Total write bytes processed (page 02, code 0005)
- Table 4.53 Read error count page (X'03')
- Table 4.56 Total read errors posted (page 03, code 0002)
- Table 4.58 Total read bytes processed (page 03, code 0005)
- Table 4.60 Verify error count page (X'05')
- Table 4.63 Total verify errors posted (page 05, code 0002)
- Table 4.65 Total verify bytes processed (page 05, code 0005)
- Table 4.67 Non-medium error count page (X'06')
- Table 4.69 Temperature (page 0D, code 0000)
- Table 4.71 Start-stop cycle counter page (X'0E')
- Table 4.73 Accounting date (page 0E, code 0002)
- Table 4.75 Start-stop cycle counter (page 0E, code 0004)
- Table 4.76 Application client page (X'0F')
- Table 4.78 Self-test result page (X'10')
- Table 4.80 Self-test results values
- Table 4.81 SAS protocol log page format
- Table 4.82 Log parameter format
- Table 4.83 SMART status page (X'2F')
- PERSISTENT RESERVE IN (5E)
- Table 4.85 PERSISTENT RESERVE IN service actions
- Table 4.86 PERSISTENT RESERVE IN parameter data for READ KEYS
- Table 4.87 PERSISTENT RESERVE IN parameter data for READ RESERVATIONS
- Table 4.88 Format of reservation descriptors
- Table 4.89 Persistent reservations scope
- Table 4.90 Persistent reservations type codes
- PERSISTENT RESERVE OUT (5F)
- Table 4.91 PERSISTENT RESERVE OUT service action codes
- Table 4.92 PERSISTENT RESERVE OUT parameter list
- Table 4.93 PERSISTENT RESERVE OUT service action and valid parameters
- REPORT LUNS (A0)
- Table 4.94 REPORT LUNS parameter list
- REPORT DEVICE IDENTIFIER (A3)
- Table 4.95 REPORT DEVICE IDENTIFIER parameter list
- SET DEVICE IDENTIFIER (A4)
- Data Access Commands
- READ EXTENDED (28)
- WRITE (0A)
- WRITE EXTENDED (2A)
- WRITE AND VERIFY (2E)
- VERIFY (2F)
- SEEK (0B)
- SEEK EXTENDED (2B)
- SYNCHRONIZE CACHE (35)
- Format Commands
- Table 4.97 Defect list format
- Table 4.98 FORMAT UNIT command parameter list configuration
- Table 4.99 Defect descriptor: byte distance from index format
- Table 4.100 Defect descriptor: physical sector address format
- Table 4.101 FORMAT UNIT command defect processing
- REASSIGN BLOCKS (07)
- Table 4.102 REASSIGN BLOCK command: defect data list configuration
- Figure 4.2 Correction of the defect descriptor
- READ DEFECT DATA (37)
- Table 4.104 Defect data format
- Table 4.106 Defect data conditions
- READ DEFECT DATA (B7)
- Maintenance, Diagnostic Commands
- Table 4.108 Self-diagnosis test
- Table 4.109 Error recovery control flags during the self-diagnosis test
- Table 4.110 SEND DIAGNOSTIC command: parameter list configuration
- Table 4.112 SEND DIAGNOSTIC parameters: page code list
- Table 4.113 SEND DIAGNOSTIC parameters: logical/physical address conversion
- Table 4.115 SELF-TEST
- RECEIVE DIAGNOSTIC RESULTS (1C)
- Table 4.117 RECEIVE DIAGNOSTIC RESULTS response data page code list
- Table 4.119 Address format
- WRITE BUFFER (3B)
- Table 4.120 WRITE BUFFER transfer mode
- Table 4.121 WRITE BUFFER command: buffer data (mode = 000, 001)
- READ BUFFER (3C)
- Table 4.124 READ BUFFER command: buffer descriptor
- READ LONG (3E)
- WRITE LONG (3F)
- WRITE SAME (41)
- Sense Data
- Table 5.1 Expanded sense data format
- Sense data basic information
- Table 5.2 Sense key inherent information
- Table 5.3 Sense key
- Table 5.4 Additional Sense Code and Additional Sense Code Qualifier
- Sense data additional information
- INIT Error Recovery Methods (Recommended)
- Sense data analysis and error recovery methods
- Table 5.5 Sense data error classification
- Table 5.6 Error recovery processing procedures
- Disk Drive Error Recovery Processing
- Auto alternate block allocation processing
- Error recovery processing control
- Table 5.7 Disk drive errors and number of retries
- chapter 6 disk media management
- Initialization during installation
- Re-initialization
- alternate block allocation processing
- Glossary
- Acronyms and Abbreviations