ABB CL-LMR 18AC1 Series manuals
CL-LMR 18AC1 Series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- About this manual
- Reading conventions
- Logic relay
- Overview
- Device overview
- CL operating principles
- Selecting main and system menu
- Status display logic relay
- Advanced status display
- Menu structure
- Selecting or toggling between menu items
- Installation
- Connecting the expansion device
- Terminals
- Supplying AC units
- Supplying DC units
- Connecting the inputs
- Connect digital DC inputs
- Connect analog DC inputs
- Connecting high-speed counters and frequency generators
- Connecting outputs
- Connect relay outputs
- Connecting transistor outputs
- Expanding inputs/outputs
- Remote expansion
- Commissioning
- Setting the menu language
- CL operating modes
- Creating your first circuit diagram
- Circuit diagram display
- From the first contact to the output coil
- Wiring
- Testing the circuit diagram
- Deleting the circuit diagram
- Wiring with the logic relay
- Operating principles
- Relays, function relays
- Saving and loading circuit diagrams
- Working with contacts and relays
- Creating and modifying connections
- Inserting and deleting a rung
- Checking the circuit diagram
- Coil functions
- Function relays
- Example function relay with timer and counter relay
- Analog value comparator/threshold value switch
- Circuit diagram display with analog value comparator
- Compatibility of AC010 devices with logic relays
- Parameter display in RUN mode
- Function of the analog value comparator function relay
- Counters
- Function of the counter function relay
- High-speed counters, CL-DC1, CL-DC2
- High-speed counters
- Text display
- Wiring a text display
- Scaling
- Text entry
- Entering a setpoint in a display
- day time switch
- Parameter display and parameter set for 7-day time switch
- Changing time switch channel
- Operating hours counter
- Value range of the operating hours counter
- Timing relays
- Parameter display and parameter set for a timing relay
- Retention
- Timing relay modes
- Function of the timing relay function block
- Examples timing relay
- Jumps
- Power flow display
- Year time switch
- Parameter display and parameter set for year time switch
- Function of the year time switch
- Master reset
- Operating modes
- Basic circuits
- Negation (coil)
- Parallel circuit
- Parallel circuit operating like a series connection of n/o contacts
- Parallel circuit operating like a series connection of n/c contacts
- Self-latching
- Impulse relay
- Cycle pulse on falling edge
- Circuit examples
- x shift register
- Running light
- Stairwell lighting
- CL settings
- Password setup
- Selecting the scope of the password
- Activating the password
- Unlock logic relay
- Changing the menu language
- Changing parameters
- Adjustable parameters for function relays
- Setting date and time
- Setting summer time start and end
- Selection of summer time start and end
- Activating input delay (debounce)
- Activating debounce (input delay)
- Activating the P buttons
- Startup behaviour
- Behaviour when the circuit diagram is deleted
- Startup behaviour for memory module
- Setting the cycle time
- Retention (non-volatile data storage)
- Setting retentive behaviour
- Deleting retentive actual values
- diagram
- Displaying device information
- Inside the logic relay
- CL operation and implications for circuit diagram creation
- Delay times for inputs and outputs
- Delay time with CL-AC1 and CL-AC2 basic units
- Delay times for the analog inputs CL-AC1, CL-DC1 and CL-DC2
- overload with CL-LST, CL-LMT and CL-LET
- Expanding CL-LMR/CL-LMT
- Function monitoring of expansion units
- Interface
- Memory module
- Loading or saving circuit diagrams
- CL-SOFT
- Logic relay with separate display module
- Device version
- What happens if
- Possible situations when creating circuit diagrams
- Event
- Appendix
- Technical data
- Special approvals
- Power supply
- Inputs
- Relay outputs
- Transistor outputs
- List of the function relays
- Available function relays
- Names of function relay
- Compatibility of the function relay parameters
- Parameter display 7-day time switch
- Glossary
- Index