3 Installing the HardwareHub InstallationMount the Hub onto the rack in the assigned equipment cabinet using the fourscrews supplied. (Figure 6) Firmly hand-tightening the screw is adequate. If the Hub isbe shelf mounted ensure that the rubber feet supplied are in place to preventblocking the ventilation holes on the underside.Figure 6CAUTION For air circulation, be sure to leave at least 25mm (one inch) spacebetween hubs and any other equipment. If mounting a hub on the rack’s bottomshelf, also leave at least 25mm (one inch) clearance from the bottom.Antenna Unit InstallationMount the Antenna unit following the system plan in the assigned location using thesupplied hardware and appropriate wall fixings. Allow space above and below theunit for adequate ventilation and to accommodate the minimum bend radius for thecoax and fibre cables according to Figure 7.CAUTION The antenna unit and associated antennas must be installed at adistance of greater than 20cm away from the proximity of operators and intendedoperation.Figure 7Issue 3 Page 10 of 31 15/11/2006