Zamel EXTA ASM-03 Instruction Manual
STAIRCASE LIGHTING TIMER ASM-03 INSTRUCTION MANUALZAMEL Sp. z o.o.ul. Zielona 27, 43-200 Pszczyna, PolandTel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04www.zamelcet.com, e-mail: marketing@zamel.plVER. 001_03.04.2012APPEARANCEThe device is designed forone-phase installation andmust be installed in accor-dance with standards validin a particular country. Thedevice should be connectedaccording to the details inclu-ded in this instruction manual. Installation, con-nection and control should be carried out by aqualified electrician staff, who act in accordan-ce with the instruction manual and the devicefunctions. Disassembling of the device is equalwith a loss of guarantee and can cause elec-tric shock. Before installation make sure theconnection cables are not under voltage. Thecruciform head screwdriver 3,5 mm should beused to install the device. Improper transport,storage, and use of the device influence itswrong functioning. It is not advisable to installthe device in the following cases: if any device’spart is missing or the device is damaged or de-formed. In case of improper functioning of thedevice contact the producer.CAUTIONFEATURESTECHNICAL DATADESCRIPTIONASM-03Input (supply) terminals: L, NInput rated voltage: 230 V ACInput voltage tolerance: -15 ÷ +10 %Power/relay supply indicator: green LEDNominal frequency: 50 / 60 HzRated power consumption: 25 mASupply/release terminals: IN, IN, INSupply/release control current: 300 μAThreshold adjustment time: 3 min ÷ 30 min (rotating potentionometer)Operation mode: ON, AUTO, OFFTime accuracy adjustment: ±10 %Time repeatability adjustment: ±5 %Relay indicator: LED redOutput contacts parameters: 1NO - 16 A / 250 V AC1 4000 VANumber of terminal clamps: 8Section of connecting cables: 0,2 ÷ 2,50 mm2Ambient temperature range: -20 ÷ +45 o COperating position: freeMounting: TH rail 35 (EN 60715)Casing protection degree: IP20 (EN 60529)Protection level: IIOvervoltage category: IIPollution degree: 2Surge voltage: 2 kV (EN 60669-1), 1 kV (EN 61000-4-5)Dimensions: monomodular (17,5 mm) 90x17,5x66 mmWeight: 76 gReference standards: EN 60669-1; EN 60669-2-1EN 61000-4-2,3,4,5,6,11● Staircase lighting control● Fluent operating time adjustmentfrom 3 to 30 minutes● Relay indicator: LED red● Input rated indicator : LED green● Mode setting option: continuous workmode (ON), or continuous work modeOFF● Cooperation with unipolar illuminatedpushbuttons● Con-blockade function● Voltage relay output – one joint ofmax 16 A load● Monomodular casing● Mounting on TH 35 railStaircase lighting timer ASM-03 isused for staircase and hall lightningcontrolling. After a signal it switches onthe lightning for a set time and then au-tomatically switches off. Working can besmoothly regulated from 3 to 30 min bypotentionometer placed on front panel ofthe automat. ASM-03 is equipped withcon-blockade function and ON/OFFfunction.Outp u t r el a ySwitch on adjustmentInput rated signalizationInput terminal (L) Input terminal (N)Relay indicator signalizationON/AUTO/OFF functionOutput terminals (IN,IN,IN)terminals (11,11,14)The symbol stands for selectivecollection of electrical andelectronic devices. Placing useddevices with other waste is notallowed |
Related manuals for Zamel EXTA ASM-03
Zamel EXTA ASM-02 Instruction Manual
Zamel EXTA ASH-02 Instruction Manual
Zamel EXTA ASP-01 Instruction Manual
Zamel EXTA ASH-01 Instruction Manual
Zamel EXTA ASH-02 Instruction Manual
Zamel EXTA ASH-01 Instruction Manual
Zamel EXTA ASN-02 Instruction Manual
Zamel exta ASP - 10 Instruction Manual
Zamel exta ZCM-32 Instruction Manual
Zamel exta ZCM-12 Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved