Contents - Table Of Contents
- Display and controls
- Default settings and firmware version, VDE-AR-N 4105 + BDEW
- Default settings and firmware version, VDE-AR-N 4110:2018-11
- Default settings and firmware version, ÖVE/ÖNORM E 8001-4-712, G83/2+G59/3
- Application and brief description
- Connection diagrams
- x PV, 2x section switch (VDE-AR-N 4105:2011)
- Multiple PV with section switch and with a series-switched NC's as feedback contacts
- Multiple PV with section switch and with a parallel-switched closing contacts as feedback
- x PV, 1x section switch with nc/normally closed contacts (VDE-AR-N 4110:2018-11)
- Important information
- Detailed description
- Functional characteristics
- Commissioning
- Control chart Pr 2-6, 11-14, 20-23
- Control chart Pr 1, 7, 10, 15
- Description of the parameters
- Display mode (last decimal point off)
- Alarm counter
- Standby counter and standby time
- Sealing
- Possible indications in display
- Technical Data
- Maintenance and repair
- Troubleshooting and measures
- Construction form V6
- Adjustment values table VDE-AR-N 4105:2011, Low Voltage Pr 1+7
- Adjustment values VDE-AR-N 4110:2018-11, higher protection Pr11+12
|
UFR1001E 12420-0701-14 Page 26 / 34 www.ziehl.de11.12 Standby counter and standby timeThe standby counter 8stby8, is increased by 1 with every standby shut-down. Up to 9999 shut-downs arecounted. That lets the UFR1001E quickly detect how often, e.g., shut-down was performed through a ripplecontrol receiver.Query the standby counter:• Change into the display mode• Press the button several times until → display 8acxx8• Press the button 2x → display 8stby8 / 8xxxx8The standby time 8stby8 indicates how long the relay was switched off by the standby mode. It is recordedwith a resolution of 1 minute and only when the control voltage is applied and if no alarm is present.Query the standby time:• Change into the display mode• Press the button several times until → display 8acxx8• Press the button 3x → display 8stby8 / 8 x.xx8 (Time LED is illuminated)Delete the standby counter and standby time (only together):• Display alarm counter8acxx8• Press the button 2x → display 8stby8 / 8xxxx8• Keep the button pressed for 2s until → display 8stby8 / 8 0811.13 Code lockYou can protect the set parameters by enabling the code lock here.The device acknowledges an incorrect entry with 8err8 (flashes three times).Adjustment process:• Select the menu item with the buttons until → display 8Code.8• Press the button 1x → display 8Pin 8 / 8 08• Set the saved pin code with the buttons (default setting is 8 5048 )• Press the button 1x → display 8Code8 / 8off 8• Use the buttons to set the desired code lock:o 8 off8 off, all parameters can be changedo 8 On8 on, no parameters can be changed• Press the button 1x → display 8Pin 8 / 8 5048• Use the buttons to set the new, desired pin code(caution: write down the pin code)• Press the button 1x Code lock on, display 8 on8 flashes three times Code lock off, display 8 off 8 flashes three times Return to menu mode, menu item code lockIf there are any problems with the code lock (pin forgotten), the lock can be switched off and the pin can bereset to 504 by keeping the Set key pressed while switching on the mains until 8Code8 / 8 off8 appearsin the display.