Contents - Table Of Contents
- Display and controls
- Default settings and firmware version, VDE-AR-N 4105 + BDEW
- Default settings and firmware version, VDE-AR-N 4110:2018-11
- Default settings and firmware version, ÖVE/ÖNORM E 8001-4-712, G83/2+G59/3
- Application and brief description
- Connection diagrams
- x PV, 2x section switch (VDE-AR-N 4105:2011)
- Multiple PV with section switch and with a series-switched NC's as feedback contacts
- Multiple PV with section switch and with a parallel-switched closing contacts as feedback
- x PV, 1x section switch with nc/normally closed contacts (VDE-AR-N 4110:2018-11)
- Important information
- Detailed description
- Functional characteristics
- Commissioning
- Control chart Pr 2-6, 11-14, 20-23
- Control chart Pr 1, 7, 10, 15
- Description of the parameters
- Display mode (last decimal point off)
- Alarm counter
- Standby counter and standby time
- Sealing
- Possible indications in display
- Technical Data
- Maintenance and repair
- Troubleshooting and measures
- Construction form V6
- Adjustment values table VDE-AR-N 4105:2011, Low Voltage Pr 1+7
- Adjustment values VDE-AR-N 4110:2018-11, higher protection Pr11+12
|
UFR1001E 12420-0701-14 Page 17 / 34 www.ziehl.deImportant informationA marked switch and a protective device must be provided in the supply line in thevicinity of the device (easily accessible) as a disconnecting element(rated current ≤ 6A).Flawless and safe operation of such a device requires proper transport and storage, professional instillationand later commissioning along with operation as intended.Only persons who are familiar with the installation, commissioning and operation of the device and who arecorrespondingly qualified for their job are permitted to work on the device. They must comply with thecontents of the operating manual, the instructions attached to the device and the pertinent safety regulationsfor the erection and operation of electrical equipment.The devices are built and certified in accordance with EN 60255 and leave the factory in a safe andtechnically flawless condition. To maintain this condition they must comply with the safety regulationsmarked in the operating manual with the headline "Caution". Failure to follow the safety regulations can leadto death, bodily injury or property damage to the device itself and to other devices and equipment.If the information contained in the operating instructions/operating manual are not sufficient, pleasecontact us directly or contact your responsible agency or representative.Instead of the industrial norms and stipulations stated in the operating manual and applicable in Europe youmust comply with the valid and applicable regulations in the country of utilisation if the device is usedoutside of the area of application.WARNINGHazards electrical voltage!Can lead to an electric shock and burns.Disconnect and de-energize before working on the system and the device.Comply with the maximum permissible temperature when installing in a switch cabinet. Ensuresufficient clearance to other devices or heat sources. If cooling is inhibited, e.g., through closeproximity to devices with increased surface temperature or interference with the cooling-air current,the permissible ambient temperature is decreased.Caution!Before you apply mains voltage to the device, make sure that the permissible controlvoltage Us on the side rating plate matches the mains voltage connected to the device!AssemblyThe device can be mounted:• Distribution panel or control panel on 35 mm rail according to EN 60715