www.dadehpardazan.ir 88594014-152 Installation2.1.3 Installation Conditions for Applicable Standards2-4• Mounting to a Location Exposed to Corrosive GasTake measures to prevent exposure to corrosive gas. Corrosive gases will not imme-diately affect the SERVOPACK, but will eventually cause electronic components andcontactor-related devices to malfunction.• Other LocationsDo not mount the SERVOPACK in locations subject to high temperatures, highhumidity, dripping water, cutting oil, dust, iron filings, or radiation.Note: When storing the SERVOPACK with the power OFF, store it in an environment with thefollowing temperature and humidity:• -20C to +85C, 90% RH or less. (with no condensation)2.1.3 Installation Conditions for Applicable StandardsApplicableStandardsUL508CEN50178, EN55011/A2 group1 classA, EN61000-6-2, EN61800-3,EN61800-5-1, EN954-1, IEC61508-1 to 4OperatingConditionsOvervoltage Category: IIIPollution degree: 2Protection class: IP10InstallationConditionsUL Standard and Low Voltage Directive:Satisfy the conditions outlined in-V Series AC SERVOPACK SGDV SafetyPrecautions (TOBP C710800 10)EMC Directive:Certification is required after installation in the user’s machine under theconditions outlined in 2.5 EMC Installation Conditions of this manual.