Getting Started2.2 Unpack and Inspect the MAXserver 1600Follow these steps:1. Carefully unpack the MAXserver 1600 shipping carton.2. Inspect the contents and make sure that you received all parts listed on the shipping order.3. Place all packing materials back into the shipping carton and save the carton. (If you need toreturn the unit to Xyplex or your distributor, you should return it in the original carton.)4. If the MAXserver 1600 has been damaged in shipping or any parts are missing, notify your Xyplexrepresentative or distributor immediately.2.3 Place MAXserver 1600 on Flat Surface or Mount on RackSelect a location for the MAXserver 1600 that meets the following requirements:Adequate Space -- A standard 19" rack or a 19" x 15" flat, stable surface such as a shelf or desktopmust be available. You can locate the MAXserver 1600 in a variety of environments, including anoffice or computer room, provided the environmental requirements are met.To reduce the possibility of dust entering the MAXserver 1600 and to allow easy inspection of theunit's front panel lights, make sure that the MAXserver is located at an optimum distance (preferablynot less than 18 inches/45 centimeters) from the floor.Environment -- Do not choose a location where the unit will be exposed to direct sunlight orsubjected to vibration. Also, the MAXserver 1600 must be installed in an environment with 20% to80% humidity, noncondensing, 0° - 40° C (32°-113° F).Place the MAXserver on the flat, stable surface you have chosen for its location or use the instructions inSection 2.3.1 to mount it in a standard 19" rack.Do not remove the MAXserver's "feet".Do not place an object on top of the MAXserver 1600that might block the air flow through the unit.+12 0590