Studer Innotec SAXtenderUser manual V4.6.0 46Elem. Description CommentVAutomaticearth-neutralconnectionThis connection is deactivated by default. In may be used in certain specificcases for automatically re-establishing the neutral system type TT (TNC, TNS,TNC-S) when the Xtender is in inverter mode. The activation is carried out viaRCC-02/-03 remote control by configuration of the parameter {1485}. Thisoperation may only be carried out by qualified personnel, under theresponsibility of these personnel, and in conformity with the local standardsand regulations. See 4.2.3 – p. 18.W GalvanicisolatorThis device (optional) is generally used to reduce the risk of electrolyticcorrosion due to the direct current when a boat is connected at the dock.XSourcereversingswitchWhen the installation has more than one supply source, it is necessary toinstall a switching device between the sources, simultaneously switching theneutral and the phase(s) of these sources. In all cases this device (manual orautomatic) must guarantee interruption of the connected source before itsconnection to another source.Y IsolationtransformerThis device (optional) prevents the risk of galvanic corrosion due to directcurrents when a boat is connected at the dock.18 MECHANICAL DIMENSION AND MOUNTING ELEMENTSPos. Description Comments25 Mounting hook-up for XTS Delivered with the unit (without screws for wall mounting)26 Mounting hook-up for XTH27 Access shutter to the topfastening screwThis flap should be resealed after tightening the screws toprevent small animals that could damage the device fromentering.19 NAMEPLATE (FIG. 1B)Pos. Denomination Description Comments30 Model Model31 Pnom*/P30* Rated power output / power for 30 minuteswith external cooling fan ECF-01Model XTS only32 Pnom/P30 Rated power output / power for 30 minutes33 Udc Battery Rated battery voltage (accepted inputrange)34 IdcCharge/inv/inv*Maximum current in charger/nominalcurrent in inverter/in inverter with externalcooling fan for XTS model35 UAC-In Maximum current at input / output See sect. 7.2 – p. 26.36 IAC-In Rated AC input voltage (input range) See sect. 7.2.2 – p. 27.37 UAC-OutRated output voltage in inverter mode(possible adjustment range in invertermode)When the transfer relay isactivated, the AC outputvoltage is equivalent to ACinput voltage38 I AC-OutInv/Inv*/maxMaximum charger current See sect. 7.2.2 – p. 27.39 SN:xxxxxxxxxx Serial no.40 IPxx Protection rating according to IEC 60529