DP200 Page 18release time will result in excessive low frequency distortion. Please thereforeensure that all limiters are bypassed during initial set-up and use the followinglimiter parameter set-ups as a starting point.High Pass Filter Frequency Attack Releaseless than 50Hz 80mS S50Hz - 200Hz 80mS M200Hz - 400Hz 60mS M400Hz - 1k3Hz 40mS M1k3Hz - 4kHz 20mS M4kHz - 20kHz 10mS MOnce set, the limiter view screen can be set ( see page 23 ) this simultaneouslydisplays the amount of gain reduction for all outputs on four separate 'over limit'meters.If required the limiter-link function can be selected via the menu system. Onceselected, if any one limiter's threshold is exceeded, equal gain reduction will beapplied to all limiters, so avoiding a dynamic change in system frequency response.EqualisationFor each output a 2 band fully parametric equaliser section is provided. This allowsfor correction of driver frequency response, or compensation for the directionalproperties of the driver to be added. In addition a powerful 6 band parametricequaliser is provided on each input. This allows full room equalisation to beperformed using the DP200 saving the cost, space and wiring requirements ofexternal units.Phase ReversePhase can be independently reversed for each output. See page 18 for moreinformation.Input ‘Base’ DelayIn addition to the time alignment delay provided on each output, overall systemdelay can be applied using this facility. See page 18 for more information.Input LevelOverall system gain can be set using this control. See page 18 for more information.