Page 18 MX Series — MX36 Operating InstructionstaxLine Monitoring1: Source Select: Choose to monitor the A, B or C input sets, or the final outputs (monitorpoint in green in diagram below) and then…2: Type Select: …chosen source type (Dante, AES, Analogue) for the set. When “OUTS” isselected, source type is disabled as all three types are fed simultaneously. There is an “OFF”state for this selection which selects monitoring from the “Pre Console Select” points in redin the signal path as below:This point allows monitoring of the actual choice of Primary and Failover selections andverification that the failover is working as expected (by deliberately disconnecting/inducing afailover situation and listening to the swap to the backup source).3: Channel Select:…within the chose A/B/C (or outputs), the channel from the set.4: Headroom Meter: This meter shows the level of the currently selected channel.