WATERGUARD Puddle Installation Manual
Also see for Puddle: User guide
Water Leak DetectionEquipmentWaterguard Puddle -Alarm OnlyInstallation Guide V21Waterguard Services Limited. Registered address: 22 Oakwell Business Centre, Oakwell View, Barnsley, SouthYorkshire, S71 1HX. Tel: 01226 244200. Email: enquiries@waterguard.co.uk.IMPORTANT! INSTALLATION MUST BE CARRIED OUT ONLY BY THOSE COMPETENT IN ELECTRICALINSTALLATION. ANY DAMAGES INCURRED DUE TO IMPROPER INSTALLATION ARE NOT COVEREDUNDER WARRANTY.Test….To check the correct installation and operation of the Puddle, rapidly press the button 5 times. This willsimulate an alarm on all channels, flashing and beeping sequentially from 1 to 5. Pressing the button oncewill silence the alarm, a second press will cancel the alarm and reset the controls. The Puddle will thenenter tracking mode when it recalibrates, this takes 4 minutes and is indicated by a yellow flashing LEDfollowed by single green to establish a new trip level after an alarm condition.To check the correct installation of each water sensing device, wet tests should be conducted on allchannels in use. This involves ensuring water contamination to the tape/feet activates the alarm on allchannels, note all channels can be tested at the same time and does not require recalibration for each one.Once all channels are tested clear the alarm.© 2021 Waterguard Services Limited, All Rights ReservedTechnical Support…. Order No:__________________Technical support and further product information is available during office hours. Please double check allelectrical connections before contacting us. Call 01226 397987 to speak with one our technical experts.Success?Power is indicated by a single white flash and beep. The unit will then flash yellow for approximately 10seconds as tracking/calibration is performed to establish a trip (moisture) level for each channel. Oncecomplete the unit will flash green and the Puddle is ready for action. The “ALARM OUT” terminal will alsoopen circuit on initial power up, in some instances it may close briefly first before opening which mayappear as a false alarm from DataCom/BMS if power is restarted to Puddle.There are no lights or sounds while the Puddle is in operation mode.IMPORTANT: PLEASE READ THIS GUIDE CAREFULLY AND IN FULL BEFORE INSTALLING. KEEPCLEAN: DO NOT LET WATER SENSING TAPE BECOME CONTAMINATED. STORAGE: KEEP IN A DRYPLACE PRIOR TO INSTALLATION TO AVOID POSSIBLE DAMAGE TO INTERNAL COMPONENTS. |
Related manuals for WATERGUARD Puddle
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved