WATERGUARD Puddle Installation Manual
Also see for Puddle: User guide
Wiring Diagram….ATTENTION…..The location of water sensing cable or any other water sensing device is critical to the effective operation ofthis system. Great care should be taken to locate away from areas likely to suffer from normal dampnessand condensation, as this may trigger false alarms. Each water sensing device must be installed in ausually dry area such as beneath the bath panel or plant room, depending on the application.In addition, it is critical to ensure that any water sensing cable or tape is positioned at least 20cm awayfrom any mains cables. This distance MUST be observed, or the sensor channels may not operatecorrectly.Waterguard Services Limited: 22 Oakwell Business Centre, Oakwell View, Barnsley, South Yorkshire, S71 1HX. Tel: 01226 244200. Email: enquiries@waterguard.co.uk. ©2021 Waterguard Services Limited, All Rights ReservedIMPORTANT: PLEASE READ THIS GUIDE IN FULL BEFORE INSTALLING.What you will have:1 x Waterguard Puddle sensor controller1 x 12V power pack OR 1 x 240V adapterWater sensing cable and/or tape, water sensing feet(please see delivery note for exact devices,quantities, and lengths where applicable).What you will need:2 Core Flex - PVC 2 Core Flat Flexible Cable(2192Y) min 0.75mm2 if connecting to BMS orWaterguard DataCom1 x single pattress boxLocation Log….Please use this space to note the water sensing device and its location for each of the five water sensingchannels in use. Secure tape out of site avoiding areas likely to become wet due to cleaning etc. Tapeheavily contaminated with dirt or sawdust must be replaced. Any tape which may have been stood on orhas been placed under heavy items will also require replacement.No / Sensing Device / LocationEg 10m water sensing tape Flat 3 – Under bath panel01 / ………………………….… / …………………………………..02 / …………………………… / ………………………………..….03 / …………………………… / ………………………….….…….04 / …………………………… / …………………………..……….05 / …………………………… / ………………………………..….Notes.Step by Step Installation….1. Fix controls to chosen area. All system components should be sited internally in areas where theyare readily accessible by the person(s) designated to use them. Areas should be clean and dry, andlight and sound levels should allow the status of all device indicators and sounders to be seen andheard. Any likelihood of tampering, vandalism and power disruption should also be considered.2. Wire each water sensing device to each of the numbered channels on the Puddle controller. Leadercable (connecting cable between the controls and sensing tape/cable) lengths are specified uponquotation and made to measure. THIS IS PURPOSE-BUILT CABLE AND CANNOT BESUBSTITUTED/EXTENDED BY ANY OTHER CABLE. Sensing tape must be secured with bespoketape clips (provided), 1 per meter and 1 each end. Ensure to record the water sensing device and itslocation using the location log opposite.3. Where applicable, use 2 core flex cable to connect the BMS or hardwire a Waterguard DataCom tothe ALARM OUT terminal.4. Connect power to the Puddle sensor using the 12V power pack or refer to the 240V adapterinstructions.No setup required. Ensure to see the reverse to check successful installation.PUDDLE SENSORPowerSTEP 4WATERSENSING TAPEAlarm OutSTEP 3Sensor ChannelsSTEP 2 |
Related manuals for WATERGUARD Puddle
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved