AC100 HIGH-PERFORMANCE VC INVERTER MANUAL FUNCTION PARAMETER SPECIFICATION142FC.51 Preset frequency lasting time Setting range:0.00-650.00s Factory default:0.00sFC.52 Swing frequency range Setting range:0.0-100.0% Factory default:0.0%FC.53 Startup frequency range Setting range:0.0-50.0% Factory default:0.0%FC.54 Swing frequency rising time Setting range:0.00-650.00s Factory default:5.00sFC.55 Swing frequency falling time Setting range:0.00-650.00s Factory default:5.00sThe inverter changes output frequency periodically with a predetermined ACC/DEC time when swing frequency runs.This feature is especially useful in the textile industry.Swing center frequency comes from given frequency of main and auxiliary channel or the set frequency in multi-speedor PLC running; swing frequency would be automatically canceled in jog and closed-loop running. When PLC and swingfrequency run simultaneously, switching between the PLC segment and swing frequency would fail; swing frequencybegins after transiting from PLC deceleration phase to PLC set frequency; press PLC stage ACC/DEC time todecelerate when stop.Swing frequency generally as follows: first accelerate to the preset frequency [FC.50] according to the acceleration timeand wait for time [FC.51], then transit according to swing center frequency according to ACC/DEC time, and then cyclerun according to the swing frequency amplitude [FC.52], startup frequency [FC.53], swing frequency rising time [FC.54]and swing frequency falling time [FC.55] until the stop command by deceleration time.LED “0” digit: swing frequency control0: invalid1: validLED “00” digit: swing frequency input modeWhen the parameter defines the swing frequency control, swing frequency input mode.0: automatic inputRun according to swing frequency [FC.50] with time decided by preset frequency [FC.51], then automatically enteringthe state of swing frequency running.1: Manual inputRun according to swing frequency [FC.50], when multifunction input terminal swing frequency input terminal is valid,enter into swing frequency state; exit when invalid, the operating frequency is maintained at the preset swing frequency[FC.50].LED “000” digit: swing amplitude control0: variable: swing amplitude AW changes with the center frequency, the rate of change, see [FC.52] definition.1: fixed: Amplitude AW is determined by the maximum frequency and [FC.52]LED “0000” digit: reservedStartup frequency amplitude: used to set the startup frequency when in swing frequency running, defined as the[FC.52] percentage.Startup frequency: Swing frequency amplitude AW × [FC.52]Swing frequency preset frequency: used to set the running frequency of inverter before entering swing frequencystate.Preset frequency Duration: when swing frequency control “00” digit of [FC.49] is set to "0" automatically input; thisparameter is used to set the swing preset frequency running duration before entering into swing frequency state; invalidwhen choosing manual input.Swing frequency amplitude: This parameter defines the frequency amplitude when in swing frequency control.Variable Swing: AW = center frequency × [FC.52]Fixed Swing: AW = maximum operating frequency [F0.09] × [FC.52]Swing frequency rising time: used to set the ACC time of swing frequency.Swing frequency falling time: used to set the DEC time of swing frequency.