VARI❋LITE® - VL2000™ SPOT LUMINAIRE U SER’S MANUAL44 02-May-03 02 .9 673 .00 01 DControl Channel FunctionsThe following control actions must be accomplished with zero time transition or with timing disabled.Discrete values must be used and not manual controls such as faders or encoders.To use control channel functions:Step 1. Select an action to be sent.Step 2. Set control channel value for desired action (for example, 84 for reset). Hold value for 3seconds.Note: A numerical keypad is required for sending values. An encoder or fader does not allow for a“snap” value change, which is required to affect the control functions.Step 3. Set control channel value to zero. (This must occur without any scaling values. Action willbe voided if other values are detected between action value and zero.)98 250 300251 31099 252 310253 310254 310100 255 Follows Cue DataTable 3-10: Control Channel FunctionsControlChannelFunctionControl Channel Value% Value For 3 Secsor GreaterAfter3 SecsDisplay On 1 1-4 0Luminaire Reset 33 81 - 87 0Lamp Off 66 165 - 171 0Lamp On 99 249 - 255 0Table 3-9: Timing Channels Map (Continued)% Value DMX = Secondswww.carlosmendoza.com.mx