Contents - Preface About this manual
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Approvals
- Safety
- Caution
- Grounding and earth fault protection
- Electro-magnetic compatibility (EMC)
- Receiving the delivery
- Type designation code
- Lifting the frames MR8 and MR9
- Accessories
- Frame MR4
- Frame MR6
- Frame MR7
- Frame MR9
- Mounting
- Wall mounting of MR5
- Wall mounting of MR6
- Wall mounting of MR7
- Wall mounting of MR8, IP21 and IP54
- Wall mounting of MR8, IP00
- Wall mounting of MR9, IP21 and IP54
- Wall mounting of MR9, IP00
- Dimensions for wall mounting, North America
- Wall mounting of MR5, North America
- Wall mounting of MR6, North America
- Wall mounting of MR7, North America
- Wall mounting of MR8, North America
- Wall mounting of MR8, UL Open Type, North America
- Wall mounting of MR9, North America
- Wall mounting of MR9, UL Open Type, North America
- Flange mounting of MR4
- Flange mounting of MR5
- Flange mounting of MR6
- Flange mounting of MR7
- Flange mounting of MR8
- Flange mounting of MR9
- Dimensions for flange mounting, North America
- Flange mounting of MR5, North America
- Flange mounting of MR6, North America
- Flange mounting of MR7, North America
- Flange mounting of MR8, North America
- Flange mounting of MR9, North America
- Cooling
- Power cabling
- UL standards on cabling
- Cable and fuse sizes, North America
- Brake resistor cables
- Preparing for the cable installation
- Frames MR8 to MR9
- Installation in a corner-grounded network
- Control unit
- Control unit cabling
- Control terminals and DIP switches
- Fieldbus connection
- Using fieldbus through an Ethernet cable
- Using fieldbus through an RS485 cable
- Installation of option boards
- The installation procedure
- Installation of a battery for the Real Time Clock (RTC)
- Commissioning and additional instructions
- Operation of the motor
- Installation in a marine environment
- The EMC jumper in MR7
- The EMC jumper in MR8
- The EMC jumper in MR9
- Maintenance
- Technical data, Vacon ® 100
- Mains voltage 380-500 V
- Mains voltage 525-600 V
- Mains voltage 525-690 V
- Brake resistor ratings
- Vacon ® 100 - technical data
- Technical data, Vacon ® 100 FLOW
- Vacon ® 100 FLOW - technical data
- Technical data, Vacon® 100 HVAC
- Overload capability
- Vacon ® 100 HVAC - technical data
- Technical data on control connections
|
8 TECHNICAL DATA, VACON® 1008.1 AC DRIVE POWER RATINGS8.1.1 MAINS VOLTAGE 208-240 VTable 34: The power ratings of Vacon® 100 in mains voltage 208-240 V, 50-60 Hz, 3~Frame DrivetypeLoadability Motor shaft powerLow * High * Maxcurrent Is2s230 V mains 230 V mainsContinuouscurrent IL[A]Inputcurrent Iin[A]10%over-loadcurrent [A]Continuouscurrent IH[A]Inputcurrent Iin[A]50%over-loadcurrent [A]10%over-load40°C[kW]50%over-load50°C[kW]10%over-load40°C[hp]50%over-load50°C[hp]MR4 0003 3.7 3.2 4.1 2.6 2.4 3.9 5.2 0.55 0.37 0.75 0.50004 4.8 4.2 5.3 3.7 3.2 5.6 7.4 0.75 0.55 1.0 0.750007 6.6 6.0 7.3 4.8 4.5 7.2 9.6 1.1 0.75 1.5 1.00008 8.0 7.2 8.8 6.6 6.0 9.9 13.2 1.5 1.1 2.0 1.50011 11.0 9.7 12.1 8.0 7.2 12.0 16.0 2.2 1.5 3.0 2.00012 12.5 10.9 13.8 9.6 8.6 16.5 19.6 3.0 2.2 4.0 3.0MR5 0018 18.0 16.1 19.8 12.5 11.5 18.8 25.0 4.0 3.0 5.0 4.00024 24.0 21.7 26.4 18.0 16.1 27.0 36.0 5.5 4.0 7.5 5.00031 31.0 27.7 34.1 25.0 22.5 37.5 46.0 7.5 5.5 10.0 7.5MR6 0048 48.0 43.8 52.8 31.0 28.5 46.5 62.0 11.0 7.5 15.0 10.00062 62.0 57.0 68.2 48.0 44.2 72.0 96.0 15.0 11.0 20.0 15.0MR7 0075 75.0 69.0 82.5 62.0 57.0 93.0 124.0 18.5 15.0 25.0 20.00088 88.0 82.1 96.8 75.0 70.0 112.5 150.0 22.0 18.5 30.0 25.00105 105.0 99.0 115.5 88.0 82.1 132.0 176.0 30.0 22.0 40.0 30.0MR8 0140 140.0 135.1 154.0 114.0 109.0 171.0 210.0 37.0 30.0 50.0 40.00170 170.0 162.0 187.0 140.0 133.0 210.0 280.0 45.0 37.0 60.0 50.00205 205.0 200.0 225.5 170.0 163.0 255.0 340.0 55.0 45.0 75.0 60.0MR9 0261 261.0 253.0 287.1 211.0 210.0 316.5 410.0 75.0 55.0 100.0 75.00310 310.0 301.0 341.0 251.0 246.0 376.5 502.0 90.0 75.0 125.0 100.0VACON · 118 TECHNICAL DATA, VACON® 1008 TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205