TIM-5H - Hardware Integration Manual Product HandlingGPS.G5-MS5-07015-A-1 u-blox proprietary Page 29your position is our focus3.1.2 TapesThe dimensions and orientations of the tapes for TIM-5H are specified in Figure 19.125.9mm32.0mm20.20 (±0.15)mm40.40 (±0.10)mm44.00 (±0.30)mm4.00mm1 = orientation of ModulesThickness of Module on Tape = 3.4(±0.1)mm26.0mmFeed DirectionFeed Direction1Figure 19: Dimensions and orientation for TIM-5H modules on tape3.2 Shipment, Storage and Handling3.2.1 Handlingu-blox 5 modules are designed and packaged to be processed in an automatic assembly line, and are shipped inTape-and-Reel.These components contain highly sensitive electronic circuitry. Handling the TIM-5H withoutproper ESD protection may destroy or damage them permanently.According to JEDEC ISP, the TIM-5H module is a moisture sensitive device. Appropriatehandling instructions and precautions are summarized in Sections 3.2.2 to 3.2.5. Read themcarefully to prevent permanent damages due to moisture intake.3.2.2 ShipmentTIM-5H modules are delivered on Tape-and-Reels in a hermetically sealed package ("dry bag") to preventmoisture intake and protect against electrostatic discharge. For protection from physical damage, the reels areindividually packed in cartons.The dry bag provides a JEDEC compliant MSD label (Moisture Sensitive Devices) describing the handlingrequirements to prevent humidity intake.