4WATER PRESSURE: A minimum of 20 pounds of water pressure is required for re-generation valve to operate effectively.ELECTRICAL FACILITIES: An uninterrupted alternating current (A/C) supply isrequired. Please make sure the voltage supply is compatible with the unit before instal-lation.EXISTING PLUMBING: Condition of existing plumbing should be free from limeand iron buildup. Piping that is built up heavily with lime and/or iron should be replaced.LOCATION OF AQUATROL TANK AND DRAIN: The Aquatrol tank should be locat-ed close to a drain to prevent air breaks and back flow.BY-PASS VALVES: Always provide for the installation of a by-pass valve if unit is notequipped with one. The Catalytic Carbon Aquatrol is equipped with a bypass valve.CAUTION: Water pressure is not to exceed 80 psi, water temperature is not to exceed110°F (43°C), and the unit cannot be subjected to freezing conditions or direct sunlight.1) Use a piece of duct tape to cover the top of the distributor tube in the tank. Be sure thedistributor tube is centered in the tank. The distributor tube should be flush with the top ofthe tank or no more than 1/4” below flush. Install the supplied funnel and pour the gravelin the tank first. Each system will ship with gravel and Catalytic Carbon media. Pour thegravel in the tank first then pour in all the Catalytic Carbon media that was shipped in thetank last. US Water does not ship “extra” media.Aquatrol Installation Instructions and SpecificationsAquatrol Tank and Control Valve PreparationInstallation, Operation and Maintenance ManualAQF-CX-100 & AQF-CX-200