PAGE 1 OF 3 0221 TH-3767H-37671-800-295-5510uline.comBATTERY OPERATEDDOUBLE SCISSORLIFT TABLETROUBLESHOOTINGOPERATING ISSUE CAUSES RECOMMENDATIONSThe lift motor does notrun.Battery cord is disconnected.Battery charge is insufficient.The fuse has been triggered.Connect the battery cord.Charge the battery.Check the fuse.The table will not raise. Low hydraulic oil.Faulty hydraulic pump.Add oil.Replace hydraulic pump.Table lowers withoutpushing the downbutton.Oil leaking from the lowering valve.Oil leaking from hydraulic circuit.Replace lowering valve.Check hydraulic circuit and repair.Oil leaking from thecylinder.Seals are worn out or damaged. Replace the seals.Oil leakage from the airinlet.Excessive oil in the reservoir. Drain the oil to the correct level.Battery will not charge. Battery is worn out. Replace battery.Charger flashing to showerror.Charger is not connected.Batteries are not connected properly.Check all connections.Check all battery connections.Para Español, vea página 2.Pour le français, consulter la page 3.