11-711. PROGRAMMING PROCEDURES 11.2 PLU DATA SETTINGPressing the ↓key instead of the ENTERkey proceeds to the next menu. Pressing the ↑keyreturns to the preceding menu.Verification label of PLU dataNET WT.SELL BYPACKED ONPRICE lbT1.000 T15.0%CCommodity NameCompulsory TareShelf LifePriceUPC#QuantityPLU#Preset TareMode FlagNOTES:1. A UPC code is made up of a combination of an entered code and an AUTO CODE. Be sureto add some - characters to the end of the AUTO CODE, or all entered codes will beignored and an AUTO CODE will become an UPC code (see ex. 1).ex. 1) enter code: 456 ex. 2) enter code 4567 ex. 3) enter code: 123456AUTO CODE: 123....AUTO CODE: 123.... AUTO CODE: 987code#: 123456code#: 123567code#: 9872. When there is no area to store PLU data, an error occurs when pressing the ENTER key.3. Changing a PLU# to number to which other PLU data is set will result in an error.4. Unit price flag may be selected as follows:1) In case of lb scalea. INSERT1 key : $ per lbb. DELETE (A) 1/2 key : $ per 1/2 lbc. RETURN 1/4 key : $ per 1/4 lb2) In case of kg scalea. INSERT 1 key : $ per 100 g or Kg (CA/QR type only)5. Tare limit should be a multiple of 5 (5, 10, 15...), up to 2.000 lb for US type and a mutiple of 2(2, 4, 6, 8...), up to 1.000 Kg for CA/QR type.6. Safe handing instructions can be printed on 57-mm wide labels only. Safe handinginstructions are printed on labels formatted for ingredient messages. Only ingredientmessage labels with 13 or more lines can be used to print safe handling instructions.Available print formats are as follows:13 (63), 15 (65), 16 (66), 23 (73), 25 (75), 26 (76), 33 (83), 35 (85), 36 (86), 41, 42, 43, 48and 49.7. Tare % indicates a percentage of tare in gross weight, which is available when the InitialSetting #8-7 is set to 1.8. When setting open price in the count mode (Initial Setting #1-6: 1), set zeros as quantity andunit price.↓ ↓ ↓Preset % TareTEC STORE(TEL) 0123-45-6789