2-9Strata CTX I&M September 2002Strata CTX100 Installation8. To mount the Expansion Cabinet, position it onto the back cover hangers.Note Position the cabinet over the bottom right hanger first, and then carefully tilt the cover over thetop two hangers.9. Slide the Expansion Cabinet to the left, feeding the data ribbon cable through the side hole of theExpansion Cabinet.10. Finish by securing the Expansion Cabinet to the Base cabinet with the two screws in front of thecabinets where they join together. The expansion cabinet left-side flange fits over the Base cabinetright side flange (see Figure 2-7).11. On the AMAU motherboard of the Expansion Cabinet, flip open the two data ribbon locks, plug inthe data ribbon and close the locks. The data ribbon cable should now be connected to the Baseand Expansion cabinets.12. Install PCBs into the Expansion Cabinet; follow the instructions in “Step 10: Install Other PCBsinto the Cabinet(s)”.Note The Base Cabinet DC power switch will be the master control for turning the DC power ofboth cabinets On/Off.13. Attach the outside covers on the Expansion Cabinet.Figure 2-7 Base and Expansion Cabinet InteriorF lip open loc ks to plug in data c able. P ushloc ks c losed onc e c able is plugged in. Makesure loc ks are c losed.L eft side of Expansion C abinet fits overthe right side of the Base C abinet.2 - S c rewsS 101 S 102 S 103 S 104 S 105 S 106 S 107 S 1085969